Reproducibility of VF, OCT, and OCTA in Glaucoma: A Prospective Multi-Visit Study.

Xu Qiong, Wong Damon, Tan Bingyao, Lim Charmaine Shi Min, Hu Qinglan, Wong Kai Lin, Zain Nuriin Athirah Binte Mohd, Husain Rahat, Wong Tina, Aung Tin, Schmetterer Leopold, Chua Jacqueline

СтатьяПеревод в очереди

Аннотация

PURPOSE: To quantify the reproducibility of visual field (VF), optical coherence tomography (OCT), and OCT angiography (OCTA) metrics in primary open-angle glaucoma (POAG).

METHODS

Thirty-eight POAG patients completed five visits over three months without treatment changes. VF, OCT, and OCTA were obtained. Eyes were classified as mild (mean deviation [MD] > -6 dB) or moderate-to-advanced (MD ≤ -6 dB). Reproducibility was assessed using 95% tolerance limits (TL), intraclass correlation coefficient (ICC), and coefficient of variation (CoV). Mixed-effects models identified factors associated with variability.

RESULTS

Thirty-eight participants (age 67 ± 9 years) included 56 mild (74%) and 20 moderate-to-advanced (26%) eyes. VF metrics demonstrated severity-dependent increases in variability, with MD TL widening from ±2 to ±4 dB, ICC decreasing from 0.95 to 0.75, and CoV increasing from 16% to 26%. OCTA metrics also showed severity-related variability, particularly for peripapillary perfusion density (CoV 5% to 9%), whereas macular OCTA parameters showed smaller changes (CoV 1% to 2%). OCT structural measures remained stable across severity stages (peripapillary retinal nerve fiber layer [pRNFL] and ganglion cell-inner plexiform layer [mGCIPL] CoV ∼2%). Worse MD predicted greater variability in VF and OCTA metrics (all P ≤ 0.046), whereas older age, longer axial length, and false-negative rate were associated with greater MD variability (all P ≤ 0.022).

CONCLUSIONS

VF and OCTA metrics showed severity-dependent variability, whereas OCT structural measures remained stable across severity stages. These findings support modality- and severity-specific thresholds for glaucoma progression.

TRANSLATIONAL RELEVANCE: This study helps clinicians better distinguish true glaucoma progression from normal test variability across VF, OCT, and OCTA measurements.

Для цитирования: Xu Qiong, Wong Damon, Tan Bingyao, Lim Charmaine Shi Min, Hu Qinglan, Wong Kai Lin, Zain Nuriin Athirah Binte Mohd, Husain Rahat, Wong Tina, Aung Tin, Schmetterer Leopold, Chua Jacqueline. Reproducibility of VF, OCT, and OCTA in Glaucoma: A Prospective Multi-Visit Study.. Translational vision science & technology. 2026. DOI: 10.1167/tvst.15.7.30.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.