MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12883-024-03952-1

Медицинская библиотека · BMC neurology · 2024

Abnormalities along the cortico-medullary junction on brain MRI caused by 1,2-dichloroethane-induced toxic encephalopathy.

Cai Dan, Kuang Liqiang, Hu Fan, Shen Yaoyao

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

1,2-dichloroethane (DCE) induced toxic encephalopathy, a rare toxic disease of the central nervous system, is mainly reported in developing countries. Although clinicians have got some understanding about the clinical and neuroimaging features of 1,2-DCE-induced toxic encephalopathy, abnormality along the cortico-medullary junction on diffusion-weighted image (DWI) mimicking neuronal intranuclear inclusion disease (NIID) has not yet been described in this entity.

CASE PRESENTATION: We reported a patient with 1,2-DCE-induced toxic encephalopathy who was admitted to our department due to a 7-day history of nausea, vomiting, and cognitive decline. Brain magnetic resonance imaging (MRI) showed symmetrical hyperintensities in bilateral subcortical white matte on T2-weghted and Fluid-attenuated inversion recovery (FLAIR) images. In addition, abnormal signal intensity could also be found in the cortico-medullary junction on DWI, mimicking NIID. After treated with glucocorticoid, dehydrating agents, neuroprotective agents, and hyperbaric oxygen, our patient received a partial recovery.

CONCLUSION

Our case highlights a special MRI finding-abnormalities along the cortico-medullary junction-that can be seen in 1,2-DCE-induced toxic encephalopathy. When confronted with patients with lesion located in the cortico-medullary junction and neuropsychiatric symptoms, our clinicians should not neglect the detailed inquiry of history of toxic exposure.

Для цитирования: Cai Dan, Kuang Liqiang, Hu Fan, Shen Yaoyao. Abnormalities along the cortico-medullary junction on brain MRI caused by 1,2-dichloroethane-induced toxic encephalopathy.. BMC neurology. 2024. DOI: 10.1186/s12883-024-03952-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.