m+Medelevator.RU
← Поиск публикаций
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2006

Comparison of transendocardial and retrograde coronary venous intramyocardial catheter delivery systems in healthy and infarcted pigs.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Baklanov D V, Moodie K M, McCarthy F E, Mandrusov E, Chiu J, Aswonge G, Cheng J, Chow M, Simons M, de Muinck E D

Аннотация

UNLABELLED: We compared two routes for myocardial delivery of therapeutics, transendocardial (TE) delivery with an intramyocardial injection catheter, and retrograde coronary venous (RCV) delivery with a balloon occlusion catheter in the interventricular vein.

METHODS: TE and RCV injection of 15 microM, neutron-activatable microspheres was compared in healthy pigs (Group I, n = 3), pigs with a 1-week-old myocardial infarction (MI; group II, n = 5), and pigs with a 2-weeks-old MI (group III, n = 4). The MI was induced by a 1-hr balloon occlusion in the LAD. Both methods were compared in the same animal using different microspheres. The RCV catheter allowed for continuous measurement of distal pressure and 2.5 x 10(6) microspheres were injected in 10 ml at 300 mmHg above balloon occlusion pressure. The TE injections were targeted to the infarct zone and 2.5 x 10(6) microspheres were distributed over 10 injections of 200 microl.

RESULTS: The retention of microspheres decreased with increase in MI age, but was comparable between devices within the groups. RCV delivery resulted in (14.3 +/- 0.9)% microsphere retention in Group I, (10.3 +/- 0.2)% in Group II, and (6.4 +/- 0.1)% in group III (P < 0.05 versus group I). Microsphere retention after TE was (15.1 +/- 0.7)% in group I, (18.9 +/- 0.6)% in group II, (4.1 +/- 0.1)% in Group III (P < 0.05 versus groups I and II). The RCV catheter delivered primarily to midventricular, antero-septal segments, whereas TE targeted apical areas predominantly.

CONCLUSIONS: Delivery efficacy was comparable between devices in each group however RCV targeted midventricular areas whereas TE targeted apical areas.