Patients' Radiation Exposure During Endovascular Abdominal Aortic Aneurysm Repair.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Mandigers Tim J, Fulgheri Irene, Pugliese Giorgia, Bissacco Daniele, Savarè Laura, Ieva Francesca, Campoleoni Mauro, van Herwaarden Joost A, Trimarchi Santi, Domanin Maurizio

Аннотация

BACKGROUND: To investigate associations between patient characteristics, intraprocedural complexity factors, and radiation exposure to patients during endovascular abdominal aortic aneurysm repair (EVAR).

METHODS: Elective standard EVAR procedures between January 2015 and December 2020 were retrospectively analyzed. Patient characteristics and intraprocedural data (i.e., type of device, endograft configuration, additional procedures, and contralateral gate cannulation time [CGCT]) were collected. Dose area product (DAP) and fluoroscopy time were considered as measurements of radiation exposure. Furthermore, effective dose (ED) and doses to internal organs were calculated using PCXMC 2.0 software. Descriptive statistics, univariable, and multivariable linear regression were applied to investigate predictors of increased radiation exposure.

RESULTS: The 99 patients were mostly male (90.9%) with a mean age of 74 ± 7 years. EVAR indications were most frequently abdominal aortic aneurysm (93.9%), penetrating aortic ulceration (2.0%), focal dissection (2.0%), or subacute rupture of infrarenal abdominal aortic aneurysm (2.0%). Median fluoroscopy time was 19.6 minutes (interquartile range [IQR], 14.1-29.4) and median DAP was 86,311 mGy cm2 (IQR, 60,160-130,385). Median ED was 23.2 mSv (IQR, 17.0-34.8) for 93 patients (93.9%). DAP and ED were positively correlated with body mass index (BMI) and CGCT. Kidneys, small intestine, active bone marrow, colon, and stomach were the organs that received the highest equivalent doses during EVAR. Higher DAP and ED values were observed using the Excluder endograft, other bi- and tri-modular endografts, and EVAR with ≥2 additional procedures. Multivariable linear regression analysis revealed that BMI, ≥2 additional procedures during EVAR, and CGCT were independent positive predictors of DAP and ED levels after accounting for endograft type.

CONCLUSIONS: Patient-related and procedure-related factors such as BMI, ≥2 additional procedures during EVAR, and CGCT resulted predictors of radiation exposure for patients undergoing EVAR, as quantified by higher DAP and ED levels. The main intraprocedural factor that increased radiation exposure was CGCT. These data can be of importance for better managing radiation exposure during EVAR.