m+Medelevator.RU
← Поиск публикаций
Journal of neurointerventional surgery · 2021

Woven EndoBridge device for ruptured aneurysms: perioperative results of a US multicenter experience.

СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Cortez Gustavo M, Akture Erinc, Monteiro Andre, Arthur Adam S, Peterson Jeremy, Dornbos David, Jabbour Pascal, Gooch M Reid, Sweid Ahmad, Tjoumakaris Stavropoula I, Delgado Almandoz Josser E, Kayan Yasha, Rai Ansaar T, Boo SoHyun, Fiorella David, Vachhani Jay, Foreman Paul, Cress Marshall, Siddiqui Adnan H, Waqas Muhammad, Aghaebrahim Amin, Sauvageau Eric, Hanel Ricardo A

Аннотация

BACKGROUND: The Woven EndoBridge (WEB) device is approved in the USA for treatment of unruptured wide-neck bifurcation aneurysms. However, the safety and effectiveness of the WEB device in the treatment of ruptured intracranial aneurysms is not clear. We aim to evaluate the perioperative safety and effectiveness of the WEB device in patients with ruptured intracranial aneurysms.

METHODS: This retrospective study, conducted at eight centers in the USA, included patients with ruptured intracranial aneurysms treated with the WEB device in the setting of subarachnoid hemorrhage (SAH). Safety outcomes included intraoperative complications such as vessel perforation, thromboembolic events, and postoperative hemorrhagic or thromboembolic complications based on radiologic imaging. The primary effectiveness outcome was adequate (complete and neck remnant) aneurysm occlusion, according to the Raymond-Roy classification.

RESULTS: A total of 91 patients with 94 ruptured intracranial aneurysms were included (mean age 57.7±15.2 years; 68.1% women; 82.9% wide-necked). Aneurysms were located in the anterior communicating artery (42/94, 44.6%), middle cerebral artery (16/94, 17%), and basilar artery (15/94, 16%). Adequate occlusion was achieved in 48.8% (41/84) and 80.0% (40/50) at discharge and last follow-up (mean of 3.4 months), respectively. At discharge, procedural-related morbidity was 3.3% (3/91) and there was no procedure-related mortality. No re-rupture or delayed aneurysm rupture was observed.

CONCLUSIONS: This study demonstrates the perioperative safety and effectiveness of the WEB device for the treatment of patients with ruptured intracranial aneurysms in the setting of SAH, with low periprocedural morbidity and mortality. Long-term follow-up is warranted.