m+Medelevator.RU
← Поиск публикаций
Clinical ophthalmology (Auckland, N.Z.) · 2020

Three-Year Outcomes of Simultaneous Accelerated Corneal Crosslinking and Femto-LASIK for the Treatment of High Myopia in Asian Eyes.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zhang Yang, Yang Ruiwen, Li Xing, Dan Dan, Yang Yanlong, Liu Yuzhu, Li Runze, Qian Jia, Dai Taiqiang, Kong Liang, Yu Xianghua, Yao Baoli

Аннотация

SIGNIFICANCE: Scanning nondiffracting Bessel beams in light-sheet fluorescence microscopy (LSFM) can expand the field of view (FOV), but side lobes of the Bessel beams produce the out-of-focus background and limit the axial resolution. Furthermore, optical aberrations degrade the image quality and affect the imaging depth.

AIM: To compensate wavefront distortions and enhance the imaging performance in LSFM, we propose a method that combines the adaptive optics (AO) with the complementary beam subtraction (CBS) method in LSFM, referred as AO-CBS.

APPROACH: In the AO-CBS method, the sensorless AO is employed to correct optical aberrations in LSFM, resulting in a notable enhancement of image contrast and signal intensity by 48%. Higher axial resolution is achieved by effectively removing the out-of-focus background through subtracting the two image stacks acquired by scanning the Bessel beam and its corresponding complementary beam.

RESULTS: The final axial resolution is improved from 2.13 ± 0.18    μ m to 1.19 ± 0.02    μ m with AO-CBS methods. The effectiveness of AO-CBS in correcting aberrations is demonstrated through imaging of fluorescent beads, Aspergillus conidia, cleared mouse liver section, and other biological tissues.

CONCLUSIONS: The AO-CBS method effectively addresses key issues existing in traditional Bessel beam-based LSFM, including the sidelobe-induced out-of-focus background, the limited axial resolution, and the degraded image quality caused by optical aberrations. The successful application of this idea in LSFM can serve as a design strategy to enhance the light-sheet-based imaging systems, thereby promoting the development and the application of LSFM and providing more powerful tools for biomedical imaging.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты