MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.amjsurg.2021.08.019

Медицинская библиотека · American journal of surgery · 2021

Perioperative transcutaneous laryngeal ultrasonography to assess vocal cord function in thyroid surgery.

Kim Do Hyun, Lee Jaeyoon, Seo Youngjun, Kim Sung Won, Hwang Se Hwan

СтатьяОбзорПеревод в очереди

Аннотация

BACKGROUND

Early diagnosis of vocal cord iatrogenic injury is crucial, as is perioperative vocal cord evaluation.

METHODS

Vocal cord mobility detected via transcutaneous laryngeal ultrasonography was compared with that detected via laryngoscopy (the reference). The vocal cord visualization rate of ultrasonography for evaluation of mobility was explored.

RESULTS

The diagnostic odds ratio of transcutaneous laryngeal ultrasonography was 303.2212 (95% CI, [86.7944; 1059.3198]). The area under the summary receiver operating characteristic curve was 0.944. The sensitivity, specificity, and negative predictive value were 0.9154 [0.8471; 0.9548], 0.9771 [0.9541; 0.9887], and 0.9915 [0.9868; 0.9946], respectively. The vocal cord visualization of ultrasonography used to evaluate vocal cord mobility was high (0.9572 [0.9091; 0.9804]).

CONCLUSIONS

Since transcutaneous laryngeal ultrasonography has the advantage in vocal cord visualization, it can be considered when laryngoscopy is unavailable or patients refuse laryngoscopy. Also, it is diagnostically accurate regardless of the used landmarks, VCP definition, and timing for application.

Для цитирования: Kim Do Hyun, Lee Jaeyoon, Seo Youngjun, Kim Sung Won, Hwang Se Hwan. Perioperative transcutaneous laryngeal ultrasonography to assess vocal cord function in thyroid surgery.. American journal of surgery. 2021. DOI: 10.1016/j.amjsurg.2021.08.019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…