DOI 10.1016/j.amjsurg.2021.08.019
Perioperative transcutaneous laryngeal ultrasonography to assess vocal cord function in thyroid surgery.
Аннотация
BACKGROUND
Early diagnosis of vocal cord iatrogenic injury is crucial, as is perioperative vocal cord evaluation.
METHODS
Vocal cord mobility detected via transcutaneous laryngeal ultrasonography was compared with that detected via laryngoscopy (the reference). The vocal cord visualization rate of ultrasonography for evaluation of mobility was explored.
RESULTS
The diagnostic odds ratio of transcutaneous laryngeal ultrasonography was 303.2212 (95% CI, [86.7944; 1059.3198]). The area under the summary receiver operating characteristic curve was 0.944. The sensitivity, specificity, and negative predictive value were 0.9154 [0.8471; 0.9548], 0.9771 [0.9541; 0.9887], and 0.9915 [0.9868; 0.9946], respectively. The vocal cord visualization of ultrasonography used to evaluate vocal cord mobility was high (0.9572 [0.9091; 0.9804]).
CONCLUSIONS
Since transcutaneous laryngeal ultrasonography has the advantage in vocal cord visualization, it can be considered when laryngoscopy is unavailable or patients refuse laryngoscopy. Also, it is diagnostically accurate regardless of the used landmarks, VCP definition, and timing for application.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.