Interdisciplinary cardiovascular and thoracic surgery · 2026
Clinical and Echocardiographic Outcomes After Aortic Valve Neocuspidization: Insights from a Large Multicentre Cohort.
СтатьяМногоцентровое исследованиеНаблюдательное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Ueno Kazuhiro, Wada Tomoyuki, Shibata Toshihiko, Abe Kazuo, Murakami Takashi, Sawa Shigeharu, Inoue Yoshito, Obayashi Tamiyuki, Kanki Kazushige, Takahashi Shoichi, Miyamoto Shinji
Аннотация
OBJECTIVES: Aortic valve neocuspidization (AVNeo) has gained widespread recognition in clinical practice; however, multicentre data describing its mid-term functional durability in real-world populations remain limited. This study aimed to evaluate the clinical and echocardiographic outcomes of AVNeo in a large multicentre cohort with extended follow-up.
METHODS: This retrospective multicentre study included 672 patients who underwent AVNeo at 16 institutions. The study population was characterized by advanced age, small body size, and a substantial burden of comorbidities. Mid-term outcomes included overall survival, freedom from reoperation, and longitudinal echocardiographic performance assessed from discharge through mid-term follow-up. Survival analyses were performed using the Kaplan-Meier method, and temporal echocardiographic changes were evaluated using linear mixed-effects models accounting for repeated measurements and centre-level clustering.
RESULTS: Early postoperative outcomes demonstrated acceptable procedural safety, with a 30-day mortality of 3.0%. Echocardiographic assessment showed functional optimization during the first postoperative year, while effective orifice area remained stable. Beyond 1 year, transvalvular gradients, peak velocity, valve area, and ventricular function remained stable up to 7 years after surgery. Estimated overall survival was 91.7% at 1 year and 79.5% at 5 years, while freedom from reoperation remained high at 99.4% at 1 year and 96.5% at 5 years.
CONCLUSIONS: In this large multicentre real-world cohort, AVNeo demonstrated stable mid-term valve performance without evidence of clinically significant progressive deterioration. These findings support the durability and reproducibility of AVNeo in routine clinical practice.
METHODS: This retrospective multicentre study included 672 patients who underwent AVNeo at 16 institutions. The study population was characterized by advanced age, small body size, and a substantial burden of comorbidities. Mid-term outcomes included overall survival, freedom from reoperation, and longitudinal echocardiographic performance assessed from discharge through mid-term follow-up. Survival analyses were performed using the Kaplan-Meier method, and temporal echocardiographic changes were evaluated using linear mixed-effects models accounting for repeated measurements and centre-level clustering.
RESULTS: Early postoperative outcomes demonstrated acceptable procedural safety, with a 30-day mortality of 3.0%. Echocardiographic assessment showed functional optimization during the first postoperative year, while effective orifice area remained stable. Beyond 1 year, transvalvular gradients, peak velocity, valve area, and ventricular function remained stable up to 7 years after surgery. Estimated overall survival was 91.7% at 1 year and 79.5% at 5 years, while freedom from reoperation remained high at 99.4% at 1 year and 96.5% at 5 years.
CONCLUSIONS: In this large multicentre real-world cohort, AVNeo demonstrated stable mid-term valve performance without evidence of clinically significant progressive deterioration. These findings support the durability and reproducibility of AVNeo in routine clinical practice.