m+Medelevator.RU
← Поиск публикаций
Interdisciplinary cardiovascular and thoracic surgery · 2026

Clinical and Echocardiographic Outcomes After Aortic Valve Neocuspidization: Insights from a Large Multicentre Cohort.

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ueno Kazuhiro, Wada Tomoyuki, Shibata Toshihiko, Abe Kazuo, Murakami Takashi, Sawa Shigeharu, Inoue Yoshito, Obayashi Tamiyuki, Kanki Kazushige, Takahashi Shoichi, Miyamoto Shinji

Аннотация

OBJECTIVES: Aortic valve neocuspidization (AVNeo) has gained widespread recognition in clinical practice; however, multicentre data describing its mid-term functional durability in real-world populations remain limited. This study aimed to evaluate the clinical and echocardiographic outcomes of AVNeo in a large multicentre cohort with extended follow-up.

METHODS: This retrospective multicentre study included 672 patients who underwent AVNeo at 16 institutions. The study population was characterized by advanced age, small body size, and a substantial burden of comorbidities. Mid-term outcomes included overall survival, freedom from reoperation, and longitudinal echocardiographic performance assessed from discharge through mid-term follow-up. Survival analyses were performed using the Kaplan-Meier method, and temporal echocardiographic changes were evaluated using linear mixed-effects models accounting for repeated measurements and centre-level clustering.

RESULTS: Early postoperative outcomes demonstrated acceptable procedural safety, with a 30-day mortality of 3.0%. Echocardiographic assessment showed functional optimization during the first postoperative year, while effective orifice area remained stable. Beyond 1 year, transvalvular gradients, peak velocity, valve area, and ventricular function remained stable up to 7 years after surgery. Estimated overall survival was 91.7% at 1 year and 79.5% at 5 years, while freedom from reoperation remained high at 99.4% at 1 year and 96.5% at 5 years.

CONCLUSIONS: In this large multicentre real-world cohort, AVNeo demonstrated stable mid-term valve performance without evidence of clinically significant progressive deterioration. These findings support the durability and reproducibility of AVNeo in routine clinical practice.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты