DOI 10.1016/j.bjan.2017.02.002
[Effects of the positive end-expiratory pressure increase on sublingual microcirculation in patients with acute respiratory distress syndrome].
Аннотация
OBJECTIVE
The aim of this study was to evaluate the impact of increased positive end-expiratory pressure on the sublingual microcirculation.
METHODS
Adult patients who were sedated, under mechanical ventilation, and had a diagnosis of circulatory shock and acute respiratory distress syndrome were included. The positive end-expiratory pressure level was settled to obtain a plateau pressure of 30cmH2O and then maintained at this level for 20minutes. Microcirculatory (obtained by videomicroscopy) and hemodynamic variables were collected at baseline and compared with those at the end of 20min.
RESULTS
Twelve patients were enrolled. Overall, the microcirculation parameters did not significantly change after increasing the positive end-expiratory pressure. However, there was considerable interindividual variability. There was a negative, moderate correlation between the changes in the De Backer score (r=-0.58, p=0.048), total vessel density (r=-0.60, p=0.039) and baseline values. The changes in total vessel density (r=0.54, p=0.07) and perfused vessel density (r=0.52, p=0.08) trended toward correlating with the changes in the mean arterial pressure.
CONCLUSION
Overall, the microcirculation parameters did not significantly change after increasing the positive end-expiratory pressure. However, at individual level, such response was heterogeneous. The changes in the microcirculation parameters could be correlated with the baseline values and changes in the mean arterial pressure.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.