Jiang Daisong, Zhang Wanting, Liu Lulu, Li Geng, Shang Xiaoke, Dong Nianguo, Yang Ye, Yang Jian, Zhang Haibo, Zhou Qing, Jian Chao, Zhao Yuan, Ni Buqing, Shao Yongfeng, Liu Jian, Wu Zhong
Аннотация
BACKGROUND: Accurate quantification of aortic valve calcification (AVC) on contrast-enhanced computed tomography angiography (CTA) is pivotal for planning surgical and transcatheter aortic valve replacement. The optimal Hounsfield unit (HU) threshold for calcification detection on contrast-enhanced images remains unresolved, and every prior validation study has relied on non-contrast Agatston scoring-itself an imaging estimate-as the reference standard. This study validated two widely used fixed HU thresholds (450 HU and 850 HU) and a self-configuring nnU-Net deep learning model against ex vivo gravimetric calcium weight as an absolute physical ground truth.
METHODS: Four hundred patients were included in a retrospective cohort study with a pre-specified temporal validation split: 300 with CT-confirmed AVC and 100 with normal aortic valves. Fifty chronologically later AVC patients who underwent elective open surgical aortic valve replacement (SAVR) within seven days of clinically indicated pre-operative contrast-enhanced CTA formed the locked surgical validation cohort; their excised native leaflets underwent standardised high-temperature ashing (550 °C, 12 h) and analytical weighing (precision 0.1 mg) to obtain gravimetric calcium mass. The remaining 350 cases served exclusively for nnU-Net development (280 training / 70 internal validation). CT-derived calcium mass-equivalent estimates were quantified on the validation cohort and compared with gravimetric weight using Pearson and Spearman correlation and Bland-Altman analysis.
RESULTS: The nnU-Net achieved the strongest observed correlation with gravimetric weight (Pearson r = 0.967; bias + 6.2 mg; RMSE 13.7 mg), significantly outperforming the 450 HU threshold for correlation (r = 0.864; bias + 36.2 mg; RMSE 42.1 mg; Steiger p < 0.001) and showing a non-significant trend toward stronger correlation than 850 HU (r = 0.929; bias + 17.5 mg; RMSE 23.9 mg; Steiger p = 0.085). Compared with 850 HU, nnU-Net provided lower bias and RMSE, although the difference in Pearson r did not reach statistical significance. The 450 HU method exhibited significant proportional bias (p = 0.024), whereas neither 850 HU nor nnU-Net did. The nnU-Net achieved a mean Dice coefficient of 0.873 and intersection-over-union of 0.812.
CONCLUSIONS: Against physically weighed calcium, nnU-Net deep learning segmentation provided the most favourable overall performance profile on contrast-enhanced CTA, with the lowest bias and RMSE and the strongest observed correlation. The improvement in Pearson correlation over 850 HU represented a non-significant trend, whereas the error and agreement metrics favoured nnU-Net. Among fixed thresholds, 850 HU substantially outperformed 450 HU, offering direct physical-rather than surrogate imaging-evidence to support 850 HU as the preferred fixed threshold in standard contrast-enhanced protocols.
METHODS: Four hundred patients were included in a retrospective cohort study with a pre-specified temporal validation split: 300 with CT-confirmed AVC and 100 with normal aortic valves. Fifty chronologically later AVC patients who underwent elective open surgical aortic valve replacement (SAVR) within seven days of clinically indicated pre-operative contrast-enhanced CTA formed the locked surgical validation cohort; their excised native leaflets underwent standardised high-temperature ashing (550 °C, 12 h) and analytical weighing (precision 0.1 mg) to obtain gravimetric calcium mass. The remaining 350 cases served exclusively for nnU-Net development (280 training / 70 internal validation). CT-derived calcium mass-equivalent estimates were quantified on the validation cohort and compared with gravimetric weight using Pearson and Spearman correlation and Bland-Altman analysis.
RESULTS: The nnU-Net achieved the strongest observed correlation with gravimetric weight (Pearson r = 0.967; bias + 6.2 mg; RMSE 13.7 mg), significantly outperforming the 450 HU threshold for correlation (r = 0.864; bias + 36.2 mg; RMSE 42.1 mg; Steiger p < 0.001) and showing a non-significant trend toward stronger correlation than 850 HU (r = 0.929; bias + 17.5 mg; RMSE 23.9 mg; Steiger p = 0.085). Compared with 850 HU, nnU-Net provided lower bias and RMSE, although the difference in Pearson r did not reach statistical significance. The 450 HU method exhibited significant proportional bias (p = 0.024), whereas neither 850 HU nor nnU-Net did. The nnU-Net achieved a mean Dice coefficient of 0.873 and intersection-over-union of 0.812.
CONCLUSIONS: Against physically weighed calcium, nnU-Net deep learning segmentation provided the most favourable overall performance profile on contrast-enhanced CTA, with the lowest bias and RMSE and the strongest observed correlation. The improvement in Pearson correlation over 850 HU represented a non-significant trend, whereas the error and agreement metrics favoured nnU-Net. Among fixed thresholds, 850 HU substantially outperformed 450 HU, offering direct physical-rather than surrogate imaging-evidence to support 850 HU as the preferred fixed threshold in standard contrast-enhanced protocols.
Предметные рубрики MeSH
HumansAortic ValveCalcinosisPredictive Value of TestsRetrospective StudiesAortic Valve StenosisDeep LearningReproducibility of ResultsContrast MediaMaleFemaleAgedAged, 80 and overComputed Tomography AngiographyRadiographic Image Interpretation, Computer-AssistedHeart Valve Prosthesis ImplantationMultidetector Computed Tomography