MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1167/tvst.4.5.7

Медицинская библиотека · Translational vision science & technology · 2015

Effect of Signal Intensity on Measurement of Ganglion Cell Complex and Retinal Nerve Fiber Layer Scans in Fourier-Domain Optical Coherence Tomography.

Zhang Xinbo, Iverson Shawn M, Tan Ou, Huang David

СтатьяПеревод в очереди

Аннотация

PURPOSE: We determined the effect of Fourier-domain optical coherence tomography (OCT) signal strength index (SSI) and cropping on retinal nerve fiber layer (RNFL) and macular ganglion cell complex (GCC) scan repeatability and measurement thickness.

METHODS

Eyes were enrolled in the longitudinal Advanced Imaging for Glaucoma Study. At each visit, three repeat scans from the optic nerve head and macular protocols were obtained. Each measurement was associated with an SSI value from 0 to 100. Measurements with similar SSI scores were grouped to calculate repeatability defined as pooled standard deviation. Within-visit analysis was used to determine how measured thickness changed in relation to change in SSI level.

RESULTS

The study included 1130 eyes of 569 patients. Cropped images yielded significantly worse repeatability and they were excluded from subsequent analyses. The within-visit repeatability for RNFL and GCC measurements were significantly better with higher signal strength, and optimal cutoffs were SSI ≥ 37 and ≥ 44, respectively. The coefficient of variation was <1.8% for RNFL scans with SSI ≥ 37 and < 2% for GCC with SSI ≥ 44. For scans above the cutoff SSI, higher SSI's were correlated with thicker RNFL among normal (slope = 0.056 μm/SSI unit, P < 0.001) eyes and glaucoma suspect and perimetric glaucoma (GSPPG) eyes (slope = 0.060 μm/SSI unit, P < 0.001), but not for perimetric glaucoma (PG) eyes. No significant correlation was found for GCC.

CONCLUSION

Repeatability of RNFL and GCC thickness measurements may be improved by excluding images with cropped anatomic features and weak signal strength below recommended SSI cutoffs.

TRANSLATIONAL RELEVANCE: Measurement precision and image quality of inner eye structure by advanced imaging modality are important for clinical diagnosis and tracking of glaucoma disease.

Для цитирования: Zhang Xinbo, Iverson Shawn M, Tan Ou, Huang David. Effect of Signal Intensity on Measurement of Ganglion Cell Complex and Retinal Nerve Fiber Layer Scans in Fourier-Domain Optical Coherence Tomography.. Translational vision science & technology. 2015. DOI: 10.1167/tvst.4.5.7.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.