MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/bioengineering13010039

Медицинская библиотека · Bioengineering (Basel, Switzerland) · 2025

A Randomized, Double-Blind, Contralateral Eye Study Comparing the Clinical Outcomes of Two Types of Silicone Hydrogel Bandage Contact Lenses After Transepithelial Photorefractive Keratectomy.

Wang Ling, Jin Jiajia, Yan Lu, Huang Kaiyan, Chen Shihao

СтатьяПеревод в очереди

Аннотация

BACKGROUND

To compare clinical outcomes of Lotrafilcon A and Balafilcon A silicone hydrogel bandage contact lenses (BCLs) following transepithelial photorefractive keratectomy (TPRK).

METHODS

A randomized, double-blind, contralateral eye study enrolled 41 TPRK patients (82 eyes), with each eye randomly assigned one BCL type. Assessments included uncorrected (UDVA) and corrected (CDVA) distance visual acuity, ocular pain and irritation, epithelial healing, limbal and conjunctival hyperemia, lens mobility, and the amount of protein deposition on the BCLs.

RESULTS

Postoperative day 1 pain score was lower in Group A (2.80 ± 2.35) than in Group B (4.44 ± 2.46, p = 0.003). Group A had significantly less protein deposition (day 3: 9.92 ± 9.82 vs. 25.75 ± 9.86 μg, p < 0.001; day 4: 9.47 ± 10.06 vs. 32.60 ± 16.71 μg, p = 0.005). No statistically significant differences were observed between the two groups in terms of corneal epithelial defect area, corneal epithelial healing time, UDVA, CDVA, limbal or conjunctival hyperemia, and lens movement.

CONCLUSIONS

Lotrafilcon A outperformed Balafilcon A in reducing ocular pain, foreign body sensation, and protein deposition, suggesting that Lotrafilcon A may be a more suitable therapeutic BCL option following TPRK.

Для цитирования: Wang Ling, Jin Jiajia, Yan Lu, Huang Kaiyan, Chen Shihao. A Randomized, Double-Blind, Contralateral Eye Study Comparing the Clinical Outcomes of Two Types of Silicone Hydrogel Bandage Contact Lenses After Transepithelial Photorefractive Keratectomy.. Bioengineering (Basel, Switzerland). 2025. DOI: 10.3390/bioengineering13010039.