Intraocular Lens Formula Comparison of Flanged Intrascleral Intraocular Lens Fixation with Double Needle Technique.

Malach Daniel S, Guest John Michael, Adam Christopher, Joffe Jonah, Le Kim, Kim Chaesik, Lin Xihui

СтатьяПеревод в очереди

Аннотация

PURPOSE: To analyze visual outcomes and accuracy of intraocular lens (IOL) calculation formulas in predicting postoperative outcomes in patients undergoing flanged intrascleral IOL fixation.

DESIGN

Case Series.

SUBJECTS: Twenty-three patients who had undergone secondary IOL placement using flanged intrascleral fixation technique.

METHODS

Retrospective chart review.

MAIN OUTCOME MEASURES: Corrected distance visual acuity (CDVA) and postoperative spherical equivalent based on manifest refraction.

RESULTS

Visual acuity improved from 20/577 to 20/58. Overall, the actual refraction was 0.06 D more myopic than predicted. Holladay 2, Sanders Retzlaff Kraff/Theoretical (SRK/T) and Barrett Universal II resulted in mild myopic surprise (-0.55, -0.18 and -0.20 D). Haigis and Hill-RBF (Radial Basis Function) resulted in mild hyperopic surprise (+0.28 and +0.28 D). Hoffer Q and Holladay 1 were the most accurate (-0.02D and -0.08 D).

CONCLUSION

Flanged intrascleral IOL fixation improved vision even in patients with other posterior segment pathologies. The effective lens positioning is likely similar to in-the-bag positioning. Hoffer Q and Holladay 1 formulas with in-the-bag calculations were the most accurate.

Для цитирования: Malach Daniel S, Guest John Michael, Adam Christopher, Joffe Jonah, Le Kim, Kim Chaesik, Lin Xihui. Intraocular Lens Formula Comparison of Flanged Intrascleral Intraocular Lens Fixation with Double Needle Technique.. Clinical ophthalmology (Auckland, N.Z.). 2023. DOI: 10.2147/opth.s389325.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.