STUDY

DESIGN

A prospective study.

OBJECTIVE

To investigate the incidence of vertebral artery (VA) occlusion and whether anterior spinal artery (ASA) is occluded in cervical facet dislocation.

SETTING

University hospital, China.

METHODS

During a 2-year period, 21 conventional patients with cervical facet dislocation were prospectively enrolled. All patients received computed tomography angiography (CTA) to assess the patency of the VA, anterior radiculomedullary arteries (ARAs), and ASA at the time of injury. Clinical data were documented, including demographics, symptomatic vertebrobasilar ischemia, American Spinal Injury Association Impairment Scale (ASIA) grades, and ASA and VA radiological characteristics.

RESULTS

VA unilateral occlusion occurred in 5 of 21 patients (24%), including 2 with unilateral facet dislocation and 3 with bilateral facet dislocation. No ASA occlusion was found in all 21 patients, including 5 with VA unilateral occlusion. No patients had symptomatic vertebrobasilar ischemia.

CONCLUSIONS

VA occlusion occurs in approximately one-fourth of cervical facet dislocations, with infrequent symptomatic vertebrobasilar ischemia. ASA is not occluded following cervical facet dislocation, even with unilateral VA occlusion.

Для цитирования: Zhang Zhengfeng. Occlusion of vertebral artery and anterior spinal artery in cervical facet dislocation: a prospective study using computed tomography angiography.. Spinal cord series and cases. 2024. DOI: 10.1038/s41394-024-00664-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.