MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/cod.12241

Медицинская библиотека · Contact dermatitis · 2014

Patch testing with methylchloroisothiazolinone/methylisothiazolinone 200 ppm aq. detects significantly more contact allergy than 100 ppm. A multicentre study within the European Environmental and Contact Dermatitis Research Group.

Bruze Magnus, Isaksson Marléne, Gruvberger Birgitta, Andersen Klaus E, Gonçalo Margarida, Goossens An, Johansen Jeanne D, Maibach Howard I, Rustemeyer Thomas, Le Coz Christophe-J, White Ian R

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

Methylchloroisothiazolinone (MCI) and methylisothiazolinone (MI) are the active ingredients in commonly used preservative systems (e.g. Kathon CG(®)). MCI/MI is present in the European baseline patch test series at 100 ppm aq. Since 1986, 200 ppm (dose 0.006 mg/cm(2)) has been used in Sweden without causing skin irritation. Centres in Spain, the United Kingdom and Ireland have also used 200 ppm in their baseline series.

OBJECTIVES

To find the optimal patch test concentration for MCI/MI.

MATERIALS AND

METHODS

MCI/MI 100 ppm aq. and MCI/MI 200 ppm aq. were simultaneously patch tested in 3300 consecutively tested dermatitis patients at eight European patch test clinics and one US patch test clinic. With the Finn Chambers(®) technique (diameter 8 mm), 15 µl was micropipetted on to the filter paper in the chamber. The corresponding volume for Van der Bend(®) chambers was 20 µl, and that for IQ Chambers(®) was 25 µl.

RESULTS

Contact allergy to MCI/MI at 100 and 200 ppm was found in 1.2% and 2.1% of patients, respectively (p < 0.001).

CONCLUSIONS

MCI/MI 200 ppm aq. (dose 0.006 mg/cm(2) ) diagnoses significantly more contact allergy than the presently used concentration of 100 ppm (dose 0.003 mg/cm(2)), without resulting in more adverse reactions. MCI/MI at 200 ppm should therefore be considered for inclusion in the European baseline test series.

Для цитирования: Bruze Magnus, Isaksson Marléne, Gruvberger Birgitta, Andersen Klaus E, Gonçalo Margarida, Goossens An, Johansen Jeanne D, Maibach Howard I, Rustemeyer Thomas, Le Coz Christophe-J, White Ian R. Patch testing with methylchloroisothiazolinone/methylisothiazolinone 200 ppm aq. detects significantly more contact allergy than 100 ppm. A multicentre study within the European Environmental and Contact Dermatitis Research Group.. Contact dermatitis. 2014. DOI: 10.1111/cod.12241.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.