MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/j.jcrs.0000000000001850

Медицинская библиотека · Journal of cataract and refractive surgery · 2026

Tolerance to intraocular lens decentration and tilt in five presbyopia-correcting intraocular lenses: SS-AS-OCT-based study.

Hu Xiaofei, Zhang Jiaqing, Zhang Yu, Yu Wenlu, Yuan Haorui, Qiu Xiaozhang, Huang Shengsong, Liu Zhenzhen, Chen Weirong, Luo Lixia, Tan Xuhua

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

PURPOSE: To compare the impact of intraocular lens (IOL) decentration and tilt on the visual performance of 5 presbyopia-correcting IOLs in patients after cataract surgery.

SETTING

Zhongshan Ophthalmic Center, Guangzhou, China.

DESIGN

Prospective, observational study.

METHODS

Patients with cataract undergoing uneventful phacoemulsification with extended depth-of-focus (EDOF) IOLs (Vivity, ZXR00) and full range-of-field (RoF) IOLs (ZMB00, TFNT00, ZFR00V) were enrolled. Each IOL group was stratified by the third quartile (Q3) of IOL tilt and decentration measured by CASIA2. Intraocular higher-order aberrations (HOAs), contrast sensitivity (CS), modulation transfer function (MTF), Strehl ratio, and patient-reported outcomes 3 months postoperatively were compared between subgroups.

RESULTS

260 patients (260 eyes) were included. Based on the Q3 values, eyes were categorized into tilt subgroups T1 (<5.63 degrees) and T2 (≥5.63 degrees), and decentration subgroups D1 (<0.24 mm) and D2 (≥0.24 mm). No significant differences in visual quality were observed between Vivity and ZXR00 subgroups. By contrast, T2 subgroups of TFNT00, ZMB00, and ZFR00V exhibited higher HOAs and coma, and lower CS, than their T1 subgroups (all P < .05). The D2 subgroup of ZFR00V showed increased HOAs and coma, and reduced CS under photopic and mesopic conditions with glare (all P < .05). The D2 subgroup of ZMB00 demonstrated higher HOAs and coma, as well as lower MTF (all P < .05). The D2 subgroup of TFNT00 reported significantly lower patient satisfaction (3.25 ± 0.46 vs 3.83 ± 0.38, P = .008).

CONCLUSIONS

EDOF IOLs (ZXR00 and Vivity) demonstrated greater tolerance to tilt and decentration compared with FULL-RoF IOLs (ZMB00, TFNT00, and ZFR00V).

Для цитирования: Hu Xiaofei, Zhang Jiaqing, Zhang Yu, Yu Wenlu, Yuan Haorui, Qiu Xiaozhang, Huang Shengsong, Liu Zhenzhen, Chen Weirong, Luo Lixia, Tan Xuhua. Tolerance to intraocular lens decentration and tilt in five presbyopia-correcting intraocular lenses: SS-AS-OCT-based study.. Journal of cataract and refractive surgery. 2026. DOI: 10.1097/j.jcrs.0000000000001850.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.