Background

To compare tilt and decentration results of two scleral fixation intraocular lens (IOL) methods of four-point scleral fixation (Akreos AO60) and the Yamane technique (AcrySof MA60AC).

Methods

Two groups were compared in terms of IOL decentration and tilt at day 30 and 2 years after surgery. Correlations between IOL tilt and decentration and previous pars plana vitrectomy (PPV), axial length (AL), refractive error (RE), astigmatism, and spherical equivalent (SE) were also analyzed.

Results

This study included 50 eyes from 47 patients: four-point fixation in 25 eyes (group 1) and Yamane technique in 25 eyes (group 2). The mean horizontal tilt was 1.66° ± 1.45° in group 1 and 5.06° ± 4.65° in group 2. The horizontal tilt value was significantly higher (p < 0.05) in group 2. The mean vertical tilt for group 1 and group 2 at two year's observation was 1.74° ± 2.16° and 3.09° ± 2.79° respectively (p = 0.02). The mean horizontal IOL decentration was 0.35 ± 0.32 mm in group 1 and 0.34 ± 0.26 mm in group 2 (p > 0.05). The mean vertical IOL decentration in group 1 was 0.34 ± 0.33 mm and in group 2 it was 0.27 ± 0.20 mm respectively (p = 0.45). No statistically significant changes in tilt and decentration time were demonstrated in both groups (p > 0.05). There was no statistically significant correlation between IOL tilt and decentration and previous PPV in both groups.

Conclusions

Both techniques provide good centration and stability IOL in aphakic eyes in the absence of capsular support.

Для цитирования: Blagun Natalia, Krix-Jachym Karolina, Rekas Marek. Long-Term Assessment of Intraocular Lens Stability, Tilt and Decentration Between Four-Point Scleral Fixation and Yamane Techniques.. Journal of clinical medicine. 2026. DOI: 10.3390/jcm15082967.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.