m+Medelevator.RU
← Поиск публикаций
Transplantation proceedings · 2022

Right Heart Echocardiography Parameters and Other Predictors to Evaluate Mechanical Cardiac Support Necessity During Lung Transplantation.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kubisa Bartosz, Kubisa Anna, Piotrowska Maria, Safranow Krzysztof, Grodzki Tomasz, Peregud-Pogorzelska Małgorzata

Аннотация

BACKGROUND: Lung transplantation (LuTx) is a challenge when right heart function fails. Mechanical circulatory support (MCS) is then necessary.

METHODS: We aimed to investigate whether preoperative transthoracic echocardiography (TTE) can predict MCS use and help to exclude the sickest patients. Between 2011 and 2018, 52 patients at our institution received LuTx and qualified for this study: 35 bilateral, 16 single, 1 lobar [1] and 1 retransplantation procedure. Of these, 22 were operated using MCS and 30 without MCS. The patients were aged between 18 and 65 years, and 23 were women. The indications were lung fibrosis for 18 patients, chronic obstructive lung disease for 16, cystic fibrosis for 15, primary pulmonary hypertension for 2 and bronchiectasis for 1. TTE was performed up to 30 days before treatment and 1 to 7 days after.

RESULTS: Patients undergoing MCS versus patients not undergoing MCS: preoperative right ventricular systolic pressure 56.5 (30) vs 37.8 (11.5) mm Hg (P = .03); tricuspid regurgitation pressure gradient 48.7 (27) vs 30.2 (10.8) mm Hg (P = .015); tricuspid annular plane systolic excursion 17.8 (4.3) vs 19.9 (2.8) mm Hg (P = .04); pulmonary artery diameter 27.5 (5.2) vs 23.9 (4.1) mm (P = .004); age 41.9 (14.1) vs 54.3 (11.8) years (P = .001). Patients who were Dead versus patients who were alive pulmonary valve acceleration time of 82.8 (24.1) vs 104.9 (27.2) ms (hazard ratio [HR] = 0.959, 95% confidence interval [CI] = 0.923-0.996 per ms, P = .02) and pulmonary artery diameter of 28.9 (5.8) vs 24.4 (4.1) mm HR = 1.225, 95% CI = 1.028-1.460 per 1 mm, P = .016 were predictors of death.

CONCLUSIONS: Preoperative TTE parameters: right ventricular systolic pressure, tricuspid regurgitation pressure gradient, tricuspid annular plane systolic excursion, and pulmonary artery diameter predicted MCS use during LuTx. Certain values of valve acceleration time and pulmonary artery diameter could help discern LuTx qualification.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты