Intralenticular intraocular foreign body after stone impact: CT and US findings.
Аннотация
INTRODUCTION
Intraocular foreign body (IOFB) is a relatively common entity in emergency departments worldwide. Appropriate ocular assessment is mandatory if an intraocular foreign body is suspected because it is associated with an increased risk of endophtalmitis and a wide range of complications including hyphaema, cataract, vitreous hemorrhage, and retinal tears and detachment.
CASE REPORT: We present a case of intralenticular intraocular foreign body after stone impact.
DISCUSSION: Ultrasonography (US) and computed tomography (CT) show an accurate location of the foreign body inside the lens. This finding enabled the surgeon to perform a phacoemulsification lens extraction with removal of the foreign body, the optimal method of removing intralenticular IOFB. To our knowledge, this is the first US and CT imaging report.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.