MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/icvts/ivaf164

Медицинская библиотека · Interdisciplinary cardiovascular and thoracic surgery · 2025

Total Arch With Hybrid Frozen Elephant Trunk Versus Branched Stented Anastomosis Frozen Elephant Trunk Repair.

Shah Aakash, Leibowitz Joshua, Lu Jeffrey, Tran Douglas, Stallings Julia, Toursavadkohi Shahab, Taylor Bradley, Ghoreishi Mehrdad

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

This study aims to evaluate the short-term outcomes of total arch replacement using 2 techniques: the branched stented anastomosis frozen elephant trunk repair (B-SAFER) under moderate hypothermia (25-28 °C), and a simplified total arch and hybrid arch frozen elephant trunk (HA-FET) reconstruction using the Thoraflex stent graft under mild hypothermia (>32 °C).

METHODS

Sixty-one patients underwent total arch replacement between June 2020 and March 2024. 25 received HA-FET, and 36 received B-SAFER. Central cannulation and cerebral debranching of the innominate and left common carotid arteries were performed before circulatory arrest in both groups. Axillary cannulation led to debranching after circulatory arrest. In the HA-FET group, snares were placed circumferentially in zone 1 and zone 2 prior to circulatory arrest and deployment of FET graft; in B-SAFER, antegrade thoracic stent graft was deployed in zone 2 with left subclavian fenestration and stenting.

RESULTS

Mean age 57.4 ± 13.1 years, with 74% male. Acute type A was the pathology in 60% of HA-FET and 58% of B-SAFER patients. HA-FET had significantly shorter circulatory arrest times (9 vs 40 minutes, P < .001) but similar cardiopulmonary bypass and cross-clamp times. The rate of concomitant major cardiac procedure was higher in HA-FET group (13/25, 52% vs 10/36, 27%, P = .066). Neurologic dysfunction (4% vs 5.4%, P = 1) and in-hospital mortality (4% vs 8.1%, P = .64) were similar. No paraplegia occurred, and renal failure requiring dialysis occurred in 12% of HA-FET and 8.1% of B-SAFER patients (P = .68).

CONCLUSIONS

Both mild hypothermic total arch with hybrid FET repair and hypothermic total arch replacement utilizing B-SAFER technique provide safe and favourable short-term outcomes. Further studies with larger cohorts and long-term follow-up are required.

Для цитирования: Shah Aakash, Leibowitz Joshua, Lu Jeffrey, Tran Douglas, Stallings Julia, Toursavadkohi Shahab, Taylor Bradley, Ghoreishi Mehrdad. Total Arch With Hybrid Frozen Elephant Trunk Versus Branched Stented Anastomosis Frozen Elephant Trunk Repair.. Interdisciplinary cardiovascular and thoracic surgery. 2025. DOI: 10.1093/icvts/ivaf164.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.