MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.mimet.2021.106394

Медицинская библиотека · Journal of microbiological methods · 2021

Comparison of the complete filtration method using an automated feces analyzer with three manual methods for stool examinations.

Aiadsakun Peechana, Sriwimol Wilaiwan, Thongbun Nannapas, Rui-On Bancha, Thiparaksaphan Kulathida, Phainuice Churai, Nuhom Chonnikarn

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Conventional diagnostic techniques using manual methods for stool examination have important limitations. Hence there is a need for improved technologies in routine clinical practice. This study aimed to compare detection rates, agreements, and diagnostic performances for stool examinations in all parameters of the complete filtration method using the Sciendox Feces Analysis System-50 automated feces analyzer with three manual methods, the direct smear, Kato's thick smear, and formalin ethyl concentration techniques. The 252 routine stool samples were examined for parasites, white blood cells (WBCs), red blood cells (RBCs), fat globules, and yeast cells using the four methods indicated above, and the complete filtration detection rates, Cohen's kappa (κ), and diagnostic performances were evaluated and compared. The detection rates of RBCs, fat globules, and yeast cells examined by the complete filtration automated method were comparable to the manual methods, but the detection rates of parasites and WBCs were significantly lower. Most methods detected the same seven parasite species, Ascaris lumbricoides, hookworm, Trichuris trichiura, Strongyloides stercoralis, Entamoeba histolytica/dispar, Blastocystis spp., and Giardia intestinalis. Pairwise agreements between the complete filtration and other methods were good to very good for all parameters showing κ values of 0.74 to 0.89. The diagnostic performances against the combined results showed complete filtration method sensitivities of 70%, 81.82%, 77.27%, 100%, and 95% for parasites, WBCs, RBCs, fat globules, and yeast cells, respectively, while the complete filtration negative predictive values (NPVs) and accuracies showed higher than 95% for all parameters. The complete filtration method using the automated feces analyzer showed high NPVs and accuracies, and good agreements with the three tested manual methods for stool examination in all parameters.

Для цитирования: Aiadsakun Peechana, Sriwimol Wilaiwan, Thongbun Nannapas, Rui-On Bancha, Thiparaksaphan Kulathida, Phainuice Churai, Nuhom Chonnikarn. Comparison of the complete filtration method using an automated feces analyzer with three manual methods for stool examinations.. Journal of microbiological methods. 2021. DOI: 10.1016/j.mimet.2021.106394.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.