MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/08820538.2026.2712546

Медицинская библиотека · Seminars in ophthalmology · 2026

Visual, Refractive, and Patient-Reported Outcomes After Unilateral Implantation of a Rotationally Asymmetric Refractive Multifocal IOL.

Zhang Hao, Gonzales Alexander L, Canto-Cerdán Mario, Plaza-Puche Ana Belén, Martínez-Abad Antonio, Yébana-Rubio Pilar, Nouzovská Kateřina, Agdgomelashvili Mariam, Alió Jorge L, Piqueras Almario Paolo, Alió Del Barrio Jorge L

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate visual, refractive, and quality-of-vision outcomes after unilateral cataract surgery or refractive lens exchange (RLE) with implantation of a rotationally asymmetric refractive multifocal intraocular lens (IOL), including the LENTIS Mplus LS-313 MF30 and LENTIS MplusX.

METHODS

Thirty-nine patients who underwent unilateral lens extraction (24 for cataract, 15 for RLE) with LENTIS Mplus multifocal IOL implantation were analyzed. Examinations were performed preoperatively and postoperatively at 1, 3, and 6 months, and at the final follow-up. Distance, intermediate, and near visual acuity, refraction, wavefront aberrations, contrast sensitivity, defocus curves, and Quality of Vision questionnaire scores were assessed.

RESULTS

At the final visit, 60.72 ± 37.75 months postoperatively, mean uncorrected and corrected distance visual acuity were 0.10 ± 0.23 and 0.01 ± 0.08 logMAR, respectively. Mean uncorrected and corrected near visual acuity were 0.10 ± 0.11 and 0.09 ± 0.17 logMAR, respectively. Mean uncorrected intermediate, corrected distance intermediate, and corrected distance near visual acuity were 0.12 ± 0.14, 0.12 ± 0.07, and 0.12 ± 0.15 logMAR, respectively. Defocus curves demonstrated broad functional vision across distance, intermediate, and near ranges. Contrast sensitivity and quality-of-vision outcomes suggested generally mild visual disturbances.

CONCLUSION

Unilateral implantation was well tolerated, with favorable monocular and binocular performance, high refractive predictability, and minimal optical side effects.

Для цитирования: Zhang Hao, Gonzales Alexander L, Canto-Cerdán Mario, Plaza-Puche Ana Belén, Martínez-Abad Antonio, Yébana-Rubio Pilar, Nouzovská Kateřina, Agdgomelashvili Mariam, Alió Jorge L, Piqueras Almario Paolo, Alió Del Barrio Jorge L. Visual, Refractive, and Patient-Reported Outcomes After Unilateral Implantation of a Rotationally Asymmetric Refractive Multifocal IOL.. Seminars in ophthalmology. 2026. DOI: 10.1080/08820538.2026.2712546.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.