MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/vec.13455

Медицинская библиотека · Journal of veterinary emergency and critical care (San Antonio, Tex. : 2001) · 2025

Splenic Doppler Resistance Index for Detection of Circulatory Shock in Dogs.

Donati Pablo Alejandro, Otero Pablo E, Tarragona Lisa, Tunesi Marcela, Flores Manuel Martín, D Alotto Santiago, Dubín Arnaldo

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To assess the splenic flow resistance index (RI) and its response to a fluid bolus in dogs showing circulatory abnormalities upon hospital admission.

DESIGN

Prospective clinical study.

SETTING

Veterinary referral hospital.

ANIMALS: Nine dogs with circulatory shock and nine dogs without circulatory abnormalities.

INTERVENTIONS: Dogs with circulatory abnormalities received an IV bolus of 30 mL/kg of balanced isotonic crystalloid fluid.

MEASUREMENTS AND MAIN

RESULTS

The splenic flow RI and the baseline aortic velocity-time integral of both groups of dogs were evaluated upon hospital admission. Measurements were repeated after the fluid bolus in dogs with circulatory shock. The Mann-Whitney U-test or the Wilcoxon rank sign test was used as appropriate. The median RI in dogs with circulatory shock was higher than that in dogs without hemodynamic disorders (median [interquartile range]: 0.64 [0.62-0.77] vs. 0.54 [0.51-0.54], P < 0.001). The best cutoff value to discriminate between the two groups was 0.61, with an area under the receiver operating characteristic curve of 1.00 (95% confidence interval [CI]: 1.00-1.00), a sensitivity of 100% (95% CI: 66.4-100), a specificity of 100% (95% CI: 66.4-100), a positive predictive value of 100% (95% CI: 66.4-100), and a negative predictive value of 100% (95% CI: 66.4-100). After fluid expansion, a significant decrease in the median splenic flow RI was observed (0.57 [0.54-0.71], P = 0.007 vs. basal).

CONCLUSIONS

The splenic flow RI may be a dependable tool for identifying circulatory shock in dogs and assessing their response to fluid therapy. Additional studies are required to evaluate the use of this index for the monitoring of organ perfusion, changes in cardiac output, and fluid responsiveness in critically ill dogs.

Для цитирования: Donati Pablo Alejandro, Otero Pablo E, Tarragona Lisa, Tunesi Marcela, Flores Manuel Martín, D Alotto Santiago, Dubín Arnaldo. Splenic Doppler Resistance Index for Detection of Circulatory Shock in Dogs.. Journal of veterinary emergency and critical care (San Antonio, Tex. : 2001). 2025. DOI: 10.1111/vec.13455.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.