MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bmj.a1331

Медицинская библиотека · BMJ (Clinical research ed.) · 2008

Drug eluting and bare metal stents in people with and without diabetes: collaborative network meta-analysis.

Stettler Christoph, Allemann Sabin, Wandel Simon, Kastrati Adnan, Morice Marie Claude, Schömig Albert, Pfisterer Matthias E, Stone Gregg W, Leon Martin B, de Lezo José Suárez, Goy Jean-Jacques, Park Seung-Jung, Sabaté Manel, Suttorp Maarten J, Kelbaek Henning, Spaulding Christian, Menichelli Maurizio, Vermeersch Paul, Dirksen Maurits T, Cervinka Pavel, De Carlo Marco, Erglis Andrejs, Chechi Tania, Ortolani Paolo, Schalij Martin J, Diem Peter, Meier Bernhard, Windecker Stephan, Jüni Peter

Сравнительное исследованиеСтатьяNetwork Meta-AnalysisПоддержка исследования: вне правительства СШАОбзорTechnical ReportПеревод в очереди

Аннотация

OBJECTIVE

To compare the effectiveness and safety of three types of stents (sirolimus eluting, paclitaxel eluting, and bare metal) in people with and without diabetes mellitus.

DESIGN

Collaborative network meta-analysis.

DATA SOURCES: Electronic databases (Medline, Embase, the Cochrane Central Register of Controlled Trials), relevant websites, reference lists, conference abstracts, reviews, book chapters, and proceedings of advisory panels for the US Food and Drug Administration. Manufacturers and trialists provided additional data.

REVIEW

METHODS

Network meta-analysis with a mixed treatment comparison method to combine direct within trial comparisons between stents with indirect evidence from other trials while maintaining randomisation. Overall mortality was the primary safety end point, target lesion revascularisation the effectiveness end point.

RESULTS

35 trials in 3852 people with diabetes and 10,947 people without diabetes contributed to the analyses. Inconsistency of the network was substantial for overall mortality in people with diabetes and seemed to be related to the duration of dual antiplatelet therapy (P value for interaction 0.02). Restricting the analysis to trials with a duration of dual antiplatelet therapy of six months or more, inconsistency was reduced considerably and hazard ratios for overall mortality were near one for all comparisons in people with diabetes: sirolimus eluting stents compared with bare metal stents 0.88 (95% credibility interval 0.55 to 1.30), paclitaxel eluting stents compared with bare metal stents 0.91 (0.60 to 1.38), and sirolimus eluting stents compared with paclitaxel eluting stents 0.95 (0.63 to 1.43). In people without diabetes, hazard ratios were unaffected by the restriction. Both drug eluting stents were associated with a decrease in revascularisation rates compared with bare metal stents in people both with and without diabetes.

CONCLUSION

In trials that specified a duration of dual antiplatelet therapy of six months or more after stent implantation, drug eluting stents seemed safe and effective in people both with and without diabetes.

Для цитирования: Stettler Christoph, Allemann Sabin, Wandel Simon, Kastrati Adnan, Morice Marie Claude, Schömig Albert, Pfisterer Matthias E, Stone Gregg W, Leon Martin B, de Lezo José Suárez, Goy Jean-Jacques, Park Seung-Jung, Sabaté Manel, Suttorp Maarten J, Kelbaek Henning, Spaulding Christian, Menichelli Maurizio, Vermeersch Paul, Dirksen Maurits T, Cervinka Pavel, De Carlo Marco, Erglis Andrejs, Chechi Tania, Ortolani Paolo, Schalij Martin J, Diem Peter, Meier Bernhard, Windecker Stephan, Jüni Peter. Drug eluting and bare metal stents in people with and without diabetes: collaborative network meta-analysis.. BMJ (Clinical research ed.). 2008. DOI: 10.1136/bmj.a1331.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.