INTRODUCTION

Radiology is a technical service that provides medical imaging for all sectors of healthcare. Hospital-acquired infections (HAIs) is a major challenge in radiology and this is exacerbated in contexts where the healthcare system is unable to provide adequate funding and attention to effective infection control measures. The objectives of this study were to audit current cleaning procedures through the observation of practices in a radiology department, and to determine the types and numbers of nosocomial pathogens present on selected radiology imaging equipment and accessories before and after decontamination.

METHODOLOGY: In phase one we observed seven radiographers to audit cleaning procedures and practices. In phase two we collected swab samples from selected radiology imaging equipment and accessories and then cultured them for identification of microbes.

RESULTS

It was observed that radiographers partially practiced infection control measures. This was due to the absence of documented protocol for infection control procedures. Our results indicated that all the selected equipment and accessories were contaminated with microorganisms pre- and post-cleaning. The identified microbes were Staphylococcus aureus, Coagulase negative Staphylococci (CoNS), Bacillus species (spp.), Shigella spp., Shigella sonnei., Klebsiella spp., Salmonella paratyphi A (S. paratyphi A), Salmonella typhi (S. typhi), Providencia rettgeri, Enterobacter spp. and Citrobacter spp. and Methicillin resistant strains of Staphylococcus aureus (MRSA).

CONCLUSIONS

The research concluded that the recommended cleaning agents did not effectively reduce the number of microorganisms making the selected equipment and accessories fomites for nosocomial pathogens.

Для цитирования: Adomako Isaac Agyekum, Venter Dalene, Sampane Donkor Eric, Engel-Hills Penelope. Radiology imaging equipment and accessories as possible fomites of nosocomial pathogens.. Journal of infection in developing countries. 2022. DOI: 10.3855/jidc.14225.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.