Impact of left bundle branch block or permanent pacemaker after transcatheter aortic valve replacement on mid-term left ventricular ejection fraction.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Merdler Ilan, Case Brian C, Ben-Dor Itsik, Chitturi Kalyan R, Fahey Heather, Hayat Fatima, Isaac Imad, Satler Lowell F, Rogers Toby, Waksman Ron
Аннотация
BACKGROUND: Conduction disturbances have uncertain implications for long-term left ventricular ejection fraction (LVEF) after transcatheter aortic valve replacement (TAVR). We aimed to examine LVEF changes in patients up to two years post-TAVR.
METHODS: We examined patients who underwent TAVR between 2012 and 2020 and underwent echocardiography follow-up. Patients were categorized into four groups: 1) Those without a permanent pacemaker (PPM) or left bundle branch block (LBBB) pre- or post-TAVR; 2) Patients with pre- and post-TAVR LBBB; 3) Individuals with preexisting PPM; and 4) Patients requiring new PPM after TAVR. LVEF was assessed at the outset of TAVR, at 30 days, 1-year, and 2-years post-TAVR.
RESULTS: The study included 730 patients: 421 (57.6 %) without conduction abnormalities, 151 (20.7 %) with post-TAVR LBBB (48 pre-existing, 103 new-onset), 63 (8.6 %) with pre-existing PPM, and 95 (13.1 %) requiring new PPM. At discharge, patients without conduction abnormalities exhibited the highest LVEF (57.4 ± 11.5 %), whereas those with pre-existing PPM had the lowest (48.1 ± 15.5 %). Over two years, LVEF remained constant in patients without conduction issues and in those with pre-existing PPM. However, patients with new LBBB experienced a 6.3 % decrease in LVEF, and those requiring new PPM showed a 4.1 % reduction.
CONCLUSION: New conduction abnormalities, such as LBBB or the need for PPM, induce a decline in LVEF post-TAVR. It is imperative to focus on the long-term monitoring of left ventricular function in patients experiencing new conduction disturbances post-TAVR.
METHODS: We examined patients who underwent TAVR between 2012 and 2020 and underwent echocardiography follow-up. Patients were categorized into four groups: 1) Those without a permanent pacemaker (PPM) or left bundle branch block (LBBB) pre- or post-TAVR; 2) Patients with pre- and post-TAVR LBBB; 3) Individuals with preexisting PPM; and 4) Patients requiring new PPM after TAVR. LVEF was assessed at the outset of TAVR, at 30 days, 1-year, and 2-years post-TAVR.
RESULTS: The study included 730 patients: 421 (57.6 %) without conduction abnormalities, 151 (20.7 %) with post-TAVR LBBB (48 pre-existing, 103 new-onset), 63 (8.6 %) with pre-existing PPM, and 95 (13.1 %) requiring new PPM. At discharge, patients without conduction abnormalities exhibited the highest LVEF (57.4 ± 11.5 %), whereas those with pre-existing PPM had the lowest (48.1 ± 15.5 %). Over two years, LVEF remained constant in patients without conduction issues and in those with pre-existing PPM. However, patients with new LBBB experienced a 6.3 % decrease in LVEF, and those requiring new PPM showed a 4.1 % reduction.
CONCLUSION: New conduction abnormalities, such as LBBB or the need for PPM, induce a decline in LVEF post-TAVR. It is imperative to focus on the long-term monitoring of left ventricular function in patients experiencing new conduction disturbances post-TAVR.
Предметные рубрики MeSH
HumansBundle-Branch BlockTranscatheter Aortic Valve ReplacementMaleStroke VolumeFemaleVentricular Function, LeftTime FactorsTreatment OutcomeAged, 80 and overAgedPacemaker, ArtificialAortic Valve StenosisRisk FactorsRetrospective StudiesCardiac Pacing, ArtificialRecovery of FunctionRisk AssessmentVentricular Dysfunction, Left