MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.mimet.2022.106478

Медицинская библиотека · Journal of microbiological methods · 2022

Evaluation of the clinical sensitivity and specificity of the BD Max™ Enteric Bacterial Panel for molecular detection of pathogens for acute gastroenteritis in the Singaporean population.

Koo Seok Hwee, Heng Ying Xuan, Jiang Boran, Ng Lily Siew Yong, Sim Diana Miao Fang, Tan Thean Yen

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: Acute gastroenteritis (AGE) is caused by a wide range of pathogens. Culture methods for the detection of bacterial pathogens is time consuming and labour intensive. This study compared a same-day-to-result commercial molecular method using BD Max™ Enteric Bacterial Panel against conventional culture and laboratory-developed PCR assays (LDTs), and characterised the epidemiology of bacterial AGE in Singapore.

METHODOLOGY: PCRs for Campylobacter spp., Salmonella spp., Shigella spp./Enteroinvasive Escherichia coli (EIEC) and Shiga toxin-producing E. coli (STEC)/Shigella dysenteriae were performed on the BD Max™ platform. Concurrent routine bacterial culture ("reference standard") was performed for Campylobacter, Salmonella, Shigella, Vibrio and Aeromonas spp. In the event of a discrepancy, an "expanded reference standard" (bacterial culture with LDT) was used.

RESULTS

There were 299 stool specimens in the study, with no bacterial pathogens detected in 190 samples (63.5%). The positive samples (n = 109,36.5%) were detected with Salmonella (n = 57,19.1%), Campylobacter (n = 28,9.4%), Vibrio parahaemolyticus (n = 6,2.0%), Shigella/EIEC (n = 6,2.0%), ETEC (n = 4,1.3%), STEC (n = 2,0.7%), Aeromonas (n = 2,0.7%), Plesiomonas shigelloides (n = 1,0.3%) and 3(1.0%) co-infections. Compared to the "expanded reference standard", conventional culture missed 38/112 (33.9%) pathogens. Conversely, testing by BD Max™ alone failed to detect 17 pathogens. BD Max™ reported seven (2.3%) false-positive results.

CONCLUSIONS

BD Max™ increased the detection rate of bacterial AGE pathogens in the panel, but was limited by the absence of detection capability for Vibrio and Aeromonas spp.

Для цитирования: Koo Seok Hwee, Heng Ying Xuan, Jiang Boran, Ng Lily Siew Yong, Sim Diana Miao Fang, Tan Thean Yen. Evaluation of the clinical sensitivity and specificity of the BD Max™ Enteric Bacterial Panel for molecular detection of pathogens for acute gastroenteritis in the Singaporean population.. Journal of microbiological methods. 2022. DOI: 10.1016/j.mimet.2022.106478.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.