MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bios.2011.01.019

Медицинская библиотека · Biosensors & bioelectronics · 2011

Label-free multiplexed virus detection using spectral reflectance imaging.

Lopez Carlos A, Daaboul George G, Vedula Rahul S, Ozkumur Emre, Bergstein David A, Geisbert Thomas W, Fawcett Helen E, Goldberg Bennett B, Connor John H, Unlü M Selim

СтатьяПоддержка NIH: внешняя программаПоддержка правительства СШАПеревод в очереди

Аннотация

We demonstrate detection of whole viruses and viral proteins with a new label-free platform based on spectral reflectance imaging. The Interferometric Reflectance Imaging Sensor (IRIS) has been shown to be capable of sensitive protein and DNA detection in a real time and high-throughput format. Vesicular stomatitis virus (VSV) was used as the target for detection as it is well-characterized for protein composition and can be modified to express viral coat proteins from other dangerous, highly pathogenic agents for surrogate detection while remaining a biosafety level 2 agent. We demonstrate specific detection of intact VSV virions achieved with surface-immobilized antibodies acting as capture probes which is confirmed using fluorescence imaging. The limit of detection is confirmed down to 3.5 × 10(5)plaque-forming units/mL (PFUs/mL). To increase specificity in a clinical scenario, both the external glycoprotein and internal viral proteins were simultaneously detected with the same antibody arrays with detergent-disrupted purified VSV and infected cell lysate solutions. Our results show sensitive and specific virus detection with a simple surface chemistry and minimal sample preparation on a quantitative label-free interferometric platform.

Для цитирования: Lopez Carlos A, Daaboul George G, Vedula Rahul S, Ozkumur Emre, Bergstein David A, Geisbert Thomas W, Fawcett Helen E, Goldberg Bennett B, Connor John H, Unlü M Selim. Label-free multiplexed virus detection using spectral reflectance imaging.. Biosensors & bioelectronics. 2011. DOI: 10.1016/j.bios.2011.01.019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.