m+Medelevator.RU
← Поиск публикаций
Journal of refractive surgery (Thorofare, N.J. : 1995) · 2022

Laboratory and Clinical Experience With a Diffractive Trifocal Intraocular Lens Sutured to an Artificial Iris.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Mayer Christian S, Son Hyeck-Soo, Łabuz Grzegorz, Baur Isabella D, Yildirim Timur M, Auffarth Gerd U, Khoramnia Ramin

Аннотация

PURPOSE: To determine in vitro, using a translational research approach before realizing the procedure in a patient with iatrogenic aphakia and partial aniridia, whether suturing a trifocal intraocular lens (IOL) to an artificial iris degrades the IOL's optical quality.

METHODS: Optical quality was analyzed by measuring the modulation transfer function (MTF) at a 3-mm aperture and at 50 and 100 lp/mm spatial frequencies. The FineVision Pod F GF IOL (PhysIOL) was assessed in two powers: two +20.00 diopters (D) (20A and 20B IOLs) and two +30.00 D (30A and 30B IOLs). The IOLs' decentration in relation to the artificial iris's center was evaluated. The laboratory results provided empirical evidence in the informed consent for surgical intervention in a patient with iatrogenic aphakia and iris defect in one eye. Clinical results were measured using the parameter of corrected distance visual acuity plus a patient self-assessment of the cosmetic appearance of the operated eye.

RESULTS: The 20A and 20B IOLs demonstrated a mean MTF reduction of up to 1.1%, whereas the 30A and 30B IOLs showed a decrease of up to 5.2% for both spatial frequencies. All lenses showed good centration levels. In the clinical case, the patient showed corrected distance visual acuity, distance-corrected near visual acuity, and distance-corrected intermediate visual acuity of 0.20, 0.20, and 0.22 logMAR, respectively. The patient was satisfied with the cosmetic outcome.

CONCLUSIONS: There was merely a slight reduction in trifocal IOL optical quality after it was sutured to an artificial iris. Clinically, the combined implantation of the artificial iris and FineVision IOL provided good functional and cosmetic outcomes. [J Refract Surg. 2022;38(1):61-68.].

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты