MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12880-026-02484-z

Медицинская библиотека · BMC medical imaging · 2026

Very high frequency ultrasonographic characteristics of poroma: a retrospective observational study.

Dong Bin, Xia Hongsheng, Xia Yan, Chai Li, Xie Bo, Liu Ying

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Poroma is a rare benign skin tumor, diagnostic challenges of which require advanced imaging. Herein we investigate the ultrasonographic manifestations and clinical value of the very high frequency(VHF) ultrasound in the auxiliary diagnosis of Poroma.

METHODS

Clinical data of 24 cases pathologically diagnosed as poroma were retrospectively analyzed by means of high-resolution VHF ultrasound, including size, location, shape, margin, boundary, internal echo and blood flow patterns.

RESULTS

VHF ultrasound examination shows that most poroma are located in the epidermis and dermis. The maximum diameter was 2.6-30 (11.86 ± 6.31) mm. The tumor has clear borders, and the echo intensity of most lesions(22/24) was heterogeneous hypoechoic. Most lesions(18/24) showed small duct-like anechoic areas, 6 lesions(6/24) were detected with punctate calcification. In terms of blood flow, most lesions(18/24) showed abundant blood flow signals, which were dendritic.

CONCLUSIONS

The VHF ultrasound lacks specificity in diagnosing poroma and currently makes accurate qualitative diagnosis difficult, but it holds significant value for assessment. It can clearly define the lesion's location, layers, number, size, boundaries, relationship to surrounding structures, and internal blood supply. This provides an objective basis for selecting the next diagnostic or treatment plan, and it can also serve as an evaluation. method for postoperative follow-up.

Для цитирования: Dong Bin, Xia Hongsheng, Xia Yan, Chai Li, Xie Bo, Liu Ying. Very high frequency ultrasonographic characteristics of poroma: a retrospective observational study.. BMC medical imaging. 2026. DOI: 10.1186/s12880-026-02484-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.