Treatment of distal anterior cerebral artery aneurysms with the Pipeline Embolization Device.

Nossek Erez, Zumofen Daniel W, Setton Avi, Potts Matthew B, Raz Eytan, Shapiro Maksim, Riina Howard A, De Miquel Maria Angeles, Chalif David J, Nelson Peter K

СтатьяПеревод в очереди

Аннотация

Aneurysms of the anterior cerebral artery (ACA) located distal to the anterior communicating artery complex (ACOM) remain challenging to treat with surgical clip reconstruction as well as with endovascular coil-embolization strategies. We have treated five complex geometry distal ACA aneurysms with endoluminal reconstruction using the Pipeline Embolization Device (PED). Two aneurysms were of the dysplastic fusiform type. Three aneurysms were of complex saccular configuration. Three aneurysms were treated electively at the outset with PED. One patient had previously undergone aborted clip reconstruction, and one was treated for recurrent aneurysm growth after coil embolization. The mean diameter of the ACA in this cohort was 1.96mm proximal to the aneurysm and 1.79mm distal to the aneurysmal segment. A single PED of 2.5mm inner diameter was the sole treatment in four cases. Two PEDs, telescopically overlapped across the aneurysm, were used in the remaining case. All devices were deployed successfully. No parent artery occlusion or stenosis was observed. In all cases an associated branch vessel arising from the vicinity of the aneurysm or incorporated into its neck was covered by the endoluminal construct. At follow-up angiography, robust antegrade flow was maintained in the jailed branch. One patient experienced asymptomatic, delayed occlusion of the jailed branch. Complete aneurysm occlusion was seen in all patients. We confirm that PED can be deployed in parent vessels smaller than 2mm diameter, and that endoluminal reconstruction with the PED may be a safe and effective treatment alternative for selected distal ACA aneurysms.

Для цитирования: Nossek Erez, Zumofen Daniel W, Setton Avi, Potts Matthew B, Raz Eytan, Shapiro Maksim, Riina Howard A, De Miquel Maria Angeles, Chalif David J, Nelson Peter K. Treatment of distal anterior cerebral artery aneurysms with the Pipeline Embolization Device.. Journal of clinical neuroscience : official journal of the Neurosurgical Society of Australasia. 2016. DOI: 10.1016/j.jocn.2016.10.041.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.