MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circinterventions.120.009669

Медицинская библиотека · Circulation. Cardiovascular interventions · 2021

Safety and Feasibility of Same-Day Discharge After Left Atrial Appendage Closure With the WATCHMAN Device.

Tan Bryan E-Xin, Boppana Leela Krishna Teja, Abdullah Abdullah S, Chuprun Dmitry, Shah Abrar, Rao Mohan, Bhatt Deepak L, Depta Jeremiah P

СтатьяПеревод в очереди

Аннотация

BACKGROUND

As the use of left atrial appendage closure (LAAC) becomes more widespread, improvements in resource utilization and cost-effectiveness are necessary. Currently, there are limited data on same-day discharge (SDD) after LAAC. We aimed to evaluate the safety and feasibility of SDD versus non-SDD in patients with nonvalvular atrial fibrillation who underwent LAAC.

METHODS

We retrospectively studied 211 patients who underwent the WATCHMAN procedure in a tertiary hospital (June 2016 to June 2019). The primary safety outcome was the composite of stroke, systemic embolism, major bleeding requiring transfusion, vascular complications requiring endovascular intervention, or death through 7 days (periprocedural) and 45 days post-procedure. The secondary outcomes were the individual components of the primary outcome and all-cause readmission. We compared the clinical outcomes of patients who had SDD and non-SDD post-procedure.

RESULTS

Patients with procedure-related complications on the day of LAAC and patients who were admitted for acute clinical events before LAAC were excluded. One hundred ninety patients were included in the final analysis. Seventy-two of 190 (38%) patients had SDD, and 118 of 190 (62%) had non-SDD. There were no statistically significant differences in the primary safety outcome through 7 days (1.4% versus 5.9%; P=0.26) and 45 days post-procedure (2.8% versus 9.3%; P=0.14) between the two groups. The secondary outcomes were similar in both groups. No patients had device-related thrombus on transesophageal echocardiography at 45 days. Only 1 patient from the non-SDD group had clinically significant peri-device flow (>5 mm) at 45 days.

CONCLUSIONS

In a selected cohort of patients who underwent successful elective LAAC with WATCHMAN without same-day procedure-related complications, the primary safety outcome and secondary outcomes through 7 and 45 days post-procedure were similar in the SDD and non-SDD groups. Our findings are hypothesis generating and warrant further investigation in prospective trials.

Для цитирования: Tan Bryan E-Xin, Boppana Leela Krishna Teja, Abdullah Abdullah S, Chuprun Dmitry, Shah Abrar, Rao Mohan, Bhatt Deepak L, Depta Jeremiah P. Safety and Feasibility of Same-Day Discharge After Left Atrial Appendage Closure With the WATCHMAN Device.. Circulation. Cardiovascular interventions. 2021. DOI: 10.1161/circinterventions.120.009669.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.