MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circinterventions.123.013083

Медицинская библиотека · Circulation. Cardiovascular interventions · 2023

Outcomes Following Transcatheter Aortic Valve Replacement for Aortic Stenosis in Patients With Type 0 Bicuspid, Type 1 Bicuspid, and Tricuspid Aortic Valves.

He Jingjing, Xiong Tian-Yuan, Yao Yi-Jun, Peng Yong, Wei Jia-Fu, Zhao Zhen-Gang, Chen Guo, Ou Yuan-Weixiang, Liu Qi, Wang Xi, Zhu Zhongkai, Yang Hao-Ran, Jia Kaiyu, Mylotte Darren, Piazza Nicolo, Prendergast Bernard, Feng Yuan, Chen Mao

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Data concerning the outcomes of transcatheter aortic valve replacement in type 0 bicuspid aortic stenosis (AS) are scarce. The study aims to compare the outcomes of transcatheter aortic valve replacement for AS in patients with type 0 bicuspid, type 1 bicuspid, and tricuspid aortic valve anatomy.

METHODS

We enrolled consecutive patients undergoing transcatheter aortic valve replacement for severe AS between 2012 and 2022 in this single-center retrospective cohort study. The primary outcome was mortality, while secondary outcomes included in-hospital complications such as stroke and pacemaker implantation and transcatheter heart valve hemodynamic performance.

RESULTS

The number of patients with AS with type 0 bicuspid, type 1 bicuspid, and tricuspid aortic valve anatomy was 328, 302, and 642, respectively. Self-expanding transcatheter heart valves were used in the majority of patients (n=1160; 91.4%). In the matched population, differences in mortality (30 days: 4.2% versus 1.7% versus 1.7%, Poverall=0.522; 1 year: 10% versus 2.3% versus 6.2%, Poverall=0.099) and all stroke (30 days: 1.0% versus 0.9% versus 0.0%, Poverall=0.765; 1 year: 1.4% versus 1.6% versus 1.3%, Poverall=NS) were nonsignificant, and the incidence of overall in-hospital complications was comparable among groups. Ascending aortic diameter was the single predictor of 1-year mortality in type 0 bicuspid patients (hazard ratio, 1.59 [95% CI, 1.03-2.44]; P=0.035). The proportion of patients with a mean residual gradient ≥20 mm Hg was the highest in those with type 0 bicuspid anatomy, although the need for permanent pacemaker implantation was the lowest in this group.

CONCLUSIONS

Major clinical outcomes of transcatheter aortic valve replacement for AS in patients with type 0 bicuspid, type 1 bicuspid, and tricuspid aortic valve anatomy are equivalent at short- and mid-term follow-up. These observations merit further exploration in prospective international registries and randomized controlled trials.

Для цитирования: He Jingjing, Xiong Tian-Yuan, Yao Yi-Jun, Peng Yong, Wei Jia-Fu, Zhao Zhen-Gang, Chen Guo, Ou Yuan-Weixiang, Liu Qi, Wang Xi, Zhu Zhongkai, Yang Hao-Ran, Jia Kaiyu, Mylotte Darren, Piazza Nicolo, Prendergast Bernard, Feng Yuan, Chen Mao. Outcomes Following Transcatheter Aortic Valve Replacement for Aortic Stenosis in Patients With Type 0 Bicuspid, Type 1 Bicuspid, and Tricuspid Aortic Valves.. Circulation. Cardiovascular interventions. 2023. DOI: 10.1161/circinterventions.123.013083.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.