DOI 10.1016/j.jtcvs.2009.04.017

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2009

Surgery for acute type A dissection using total arch replacement combined with stented elephant trunk implantation: experience with 107 patients.

Sun Li-Zhong, Qi Rui-Dong, Chang Qian, Zhu Jun-Ming, Liu Yong-Min, Yu Cun-Tao, Lv Bin, Zheng Jun, Tian Liang-Xin, Lu Jin-Guo

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

In patients with acute type A dissection, it is controversial whether to use a more aggressive strategy with extended aortic replacement to improve long-term outcome or to use a conventional strategy with limited ascending aortic or hemiarch replacement to circumvent a life-threatening situation.

METHODS

Between April 2003 and June 2007, 107 patients (17 women, 90 men; mean age, 45 +/- 11 years; range, 17-78 years) with acute type A dissection underwent total arch replacement combined with stented elephant trunk implantation under hypothermic cardiopulmonary bypass and selective cerebral perfusion. Computed tomography was performed to evaluate the residual false lumen in the descending aorta during follow-up.

RESULTS

Thirty-day mortality was 3.74% (4/107 patients), and in-hospital mortality was 4.67% (5/107 patients). Spinal cord injury was observed in 3 patients (1 patient with left lower-extremity paraparesis and 2 patients with paraplegia). Cerebral infarction was observed in 3 patients, ventilator support exceeding 5 days was required in 9 patients, and rebleeding was observed in 4 patients. During a mean follow-up of 35 +/- 14 months, 3 patients died and 3 patients were lost to follow-up. On postoperative computed tomography, complete thrombus formation was observed around the stented elephant trunk in 95% of patients (95/100) and at the diaphragmatic level in 69% of patients (69/100).

CONCLUSION

Low morbidity and mortality were achieved using total arch replacement combined with stented elephant trunk implantation. These encouraging surgical results and postoperative outcomes favor this more aggressive procedure for acute type A dissection.

Для цитирования: Sun Li-Zhong, Qi Rui-Dong, Chang Qian, Zhu Jun-Ming, Liu Yong-Min, Yu Cun-Tao, Lv Bin, Zheng Jun, Tian Liang-Xin, Lu Jin-Guo. Surgery for acute type A dissection using total arch replacement combined with stented elephant trunk implantation: experience with 107 patients.. The Journal of thoracic and cardiovascular surgery. 2009. DOI: 10.1016/j.jtcvs.2009.04.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.