OBJECTIVE

To evaluate the efficacy and complications of a novel surgical technique for cicatricial lower lid ectropion that uses a vertical-to-horizontal (V-to-H) rotational myocutaneous flap procedure (Tsai procedure).

METHODS

We performed the V-to-H rotational myocutaneous flap procedure on 20 eyelids in 20 patients with mild to moderate cicatricial lower lid ectropion. A vertical myocutaneous flap was created from the anterior lamella of the vertical pedicle in the lateral third of the lower eyelid. Following a horizontal relaxing incision from the base of the flap, a vertical myocutaneous flap was created and rotated to horizontal. Two patients with combined cicatricial ectropion and paralytic lagophthalmos simultaneously underwent additional lateral tarsorrhaphy.

RESULTS

After a minimum follow-up period of 6 months, all patients showed good anatomical and functional improvement with decreased dependence on topical lubricants and a satisfactory cosmetic appearance. Two patients with combined cicatricial and paralytic ectropion had mild residual asymptomatic lagophthalmos. No patients required further revision surgery and there were no complications or recurrence.

CONCLUSION

The V-to-H rotational myocutaneous flap technique was an effective and simple one-stage procedure for correcting cicatricial lower lid ectropion. It lengthened the anterior lamella and tightened horizontal eyelid laxity without the need for a free skin graft.

Для цитирования: Chang Yu-Fan, Tsai Chieh-Chih, Kau Hui-Chuan, Liu Catherine Jui-Ling. Vertical-to-Horizontal Rotational Myocutaneous Flap for Repairing Cicatricial Lower Lid Ectropion: A Novel Surgical Technique.. BioMed research international. 2017. DOI: 10.1155/2017/8614580.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.