MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3174/ajnr.a9125

Медицинская библиотека · AJNR. American journal of neuroradiology · 2026

Longitudinal Analysis of Location- and Growth-Associated Hemodynamics in Matched Paraclinoid Aneurysms.

Chien Aichi, Sharma Latisha, Chang Warren, Colby Geoffrey, Salamon Noriko

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: Predicting intracranial aneurysm growth remains difficult, with relatively few widely accepted predictors beyond aneurysm size, location, and patient age. This study investigated the relationship of vascular morphology and hemodynamics to aneurysm location and growth using a matched pairs study design that limited the influence of other predictors.

MATERIALS AND

METHODS

Longitudinally followed ICA aneurysms identified as growing or stable were matched by size and location, based on their proximity to either the ophthalmic arteries, superior hypophyseal arteries, or posterior communicating arteries (PComA). The 34 aneurysms (17 pairs) were monitored with 3D CTA imaging for an average of 4.10 (1.98) years. Three longitudinal image studies for each aneurysm were collected and used to reconstruct models of arterial geometry. These models were used to analyze morphology and hemodynamics over time with computational fluid dynamics simulation. Results were analyzed with the Wilcoxon signed-rank test and longitudinal multivariate models were built with generalized estimating equations clustered according to each aneurysm.

RESULTS

Higher average flow (P < .01) was observed at the aneurysm inlet and lower average pulsatility index at the outlet (P < .05) of aneurysms near the PComA. Over time, morphologic metrics related to size differed between paired aneurysms, but shape metrics did not. Pulsatility index at the aneurysm body and outlet differed between paired aneurysms (P < .01). Modeling identified correlates of aneurysm size including aneurysm flow and wall shear stress pulsatility index and generally demonstrated high correlation between different time points (0.94). The models showed a strong association between the attachment of the nearby artery to the aneurysm and growth.

CONCLUSIONS

Significant differences in hemodynamics were observed between nearby aneurysm locations. Despite the relatively small sample size, longitudinally measured hemodynamics and general aneurysm morphology were significant correlates for aneurysm growth and size, as well as possible predictors of future aneurysm growth.

Для цитирования: Chien Aichi, Sharma Latisha, Chang Warren, Colby Geoffrey, Salamon Noriko. Longitudinal Analysis of Location- and Growth-Associated Hemodynamics in Matched Paraclinoid Aneurysms.. AJNR. American journal of neuroradiology. 2026. DOI: 10.3174/ajnr.a9125.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.