Piggyback Photochromic Contact Lens for Visual Rehabilitation and Photophobia Management in Traumatic Aniridia.

Miyoshi Letícia H, Hollaender Marianna A, Giglio Veronica B, Villela Flavio F, Alves Milton R

Клинический случайСтатьяПеревод в очереди

Аннотация

We report herein a case of fitting with a photochromic silicone hydrogel contact lens under a rigid gas-permeable lens (piggyback system) for photophobia and low vision correction after traumatic aniridia and aphakia. A 40-year-old woman was referred to our practice for contact lens fitting in her right eye, which was left aphakic after an open globe injury. She also presented traumatic aniridia in the right eye, and her left eye had been previously eviscerated. A successful fitting was obtained with a photochromic silicone hydrogel (senofilcon A) contact lens, with a Dk/t of 121 × 10-9, under an aspheric design, +13.00 D rigid gas-permeable lens. The patient displayed visual acuity and contrast sensitivity improvement and reported decreased photophobia.

Для цитирования: Miyoshi Letícia H, Hollaender Marianna A, Giglio Veronica B, Villela Flavio F, Alves Milton R. Piggyback Photochromic Contact Lens for Visual Rehabilitation and Photophobia Management in Traumatic Aniridia.. Eye & contact lens. 2021. DOI: 10.1097/icl.0000000000000833.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.