Use of the Inspiris valve in the native right ventricular outflow tract is associated with early prosthetic regurgitation.

Nguyen Stephanie N, Vinogradsky Alice V, Sevensky Riley, Crystal Matthew A, Bacha Emile A, Goldstone Andrew B

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The Inspiris Resilia prosthesis (Edwards Lifesciences) has been increasingly used in the pulmonic position with limited performance data. We sought to investigate its durability as a surgical pulmonary valve replacement (PVR).

METHODS

We retrospectively reviewed patients who underwent PVR or conduit replacement with an Inspiris or non-Inspiris valve/conduit from 2018 to 2022. The primary end point was freedom from a composite of at least moderate pulmonary regurgitation, pulmonary stenosis, or valve/conduit reintervention. Secondary end points were individual components of the composite outcome. To account for baseline differences, propensity matching identified 70 patient pairs.

RESULTS

A total of 227 patients (median age: 19.3 years [interquartile range, 11.8-34.4]) underwent PVR or conduit replacement (Inspiris: n = 120 [52.9%], non-Inspiris: n = 107 [47.1%]). Median follow-up was 26.6 months [interquartile range, 12.4-41.1]. Among matched patients, 2-year freedom from valve failure was lower in the Inspiris group (53.5 ± 9.3% vs 78.5 ± 5.9%, P = .03), as was freedom from at least moderate pulmonary regurgitation (54.2 ± 9.6% vs 86.4 ± 4.9%, P < .01). There was no difference in 2-year freedom from at least moderate pulmonary stenosis (P = .61) or reintervention (P = .92). Inspiris durability was poorer when implanted in the native right ventricular outflow tract compared with as a conduit, with 18-month freedom from valve failure of 59.0 ± 9.5% versus 85.9 ± 9.5% (P = .03).

CONCLUSIONS

Early durability of the Inspiris valve is poor when implanted in the native right ventricular outflow tract; its unique design may be incompatible with the compliant pulmonary root. Modified implantation techniques or alternative prostheses should be considered.

Для цитирования: Nguyen Stephanie N, Vinogradsky Alice V, Sevensky Riley, Crystal Matthew A, Bacha Emile A, Goldstone Andrew B. Use of the Inspiris valve in the native right ventricular outflow tract is associated with early prosthetic regurgitation.. The Journal of thoracic and cardiovascular surgery. 2023. DOI: 10.1016/j.jtcvs.2023.04.018.