MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081597x-20251024-02

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2025

Rotationally Asymmetric Refractive Low Addition Multifocal IOL Implantation in Patients With Previous Hyperopic Corneal Laser Refractive Surgery.

Zhang Hao, Gonzales Alexander L, Canto-Cerdan Mario, Plaza-Puche Ana Belen, Martínez-Abad Antonio, Yebana-Rubio Pilar, Nouzovská Kateřina, Alió Jorge L, Piqueras Almario Paolo, Alió Del Barrio Jorge L

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

PURPOSE: To evaluate visual, refractive, and quality-of-vision outcomes after cataract surgery with a low-addition rotationally asymmetric refractive multifocal intraocular lens (Lentis Comfort Mplus LS-313 MF15; Teleon) in eyes with prior hyperopic corneal laser refractive surgery.

METHODS

This was a retrospective observational study of 26 eyes (26 patients) implanted with the LENTIS Comfort Mplus LS-313 MF15 after uneventful surgery. Distance, intermediate, and near visual acuity, manifest refraction, ocular/corneal wavefront aberrations, contrast sensitivity, and defocus curves were assessed preoperatively and at 1, 3, and 6 months and at the final visit. Subjective quality was measured with the Quality of Vision (QoV) questionnaire.

RESULTS

At 6 months and the final visit, uncorrected (UDVA), corrected (CDVA), uncorrected near (UNVA), and corrected near (CNVA) visual acuity improved to 0.10 ± 0.14, 0.05 ± 0.06, 0.27 ± 0.22, and 0.08 ± 0.10 logarithm of the minimum angle of resolution (logMAR), respectively (all P < .05). UIVA and CDIVA were 0.12 ± 0.07 and 0.10 ± 0.09 logMAR, respectively. Refractive cylinder decreased to -0.40 ± 0.38 diopters (D) (P < .05); mean spherical equivalent at 6 months was 0.00 ± 0.70 D. Ocular root mean square for total, astigmatism, coma, asymmetry, HOAs, spherical-like, and coma-like aberrations were 0.59 ± 0.36, 0.42 ± 0.28, 0.20 ± 0.12, 0.05 ± 0.03, 0.39 ± 0.28, 0.16 ± 0.12, and 0.30 ± 0.20 µm, respectively. Defocus showed 0.05 ± 0.01 logMAR at 0.00 D, 0.13 ± 0.01 at -1.50 D, and 0.27 ± 0.20 at -2.50 D; contrast sensitivity remained within normal limits. QoV scores were 32.97 ± 24.31 (frequency), 30.47 ± 22.19 (severity), and 28.59 ± 21.32 (bothersomeness). Corneal higher order aberrations (HOAs) and angle kappa correlated with postoperative uncorrected acuity, especially at intermediate and near.

CONCLUSIONS

The aberration-neutral, rotationally asymmetric LENTIS Comfort Mplus LS-313 MF15 provided safe, predictable rehabilitation in eyes after hyperopic corneal surgery, with high-quality distance/intermediate vision and low photic phenomena. Preoperative HOAs and angle kappa significantly influenced postoperative uncorrected vision.

Для цитирования: Zhang Hao, Gonzales Alexander L, Canto-Cerdan Mario, Plaza-Puche Ana Belen, Martínez-Abad Antonio, Yebana-Rubio Pilar, Nouzovská Kateřina, Alió Jorge L, Piqueras Almario Paolo, Alió Del Barrio Jorge L. Rotationally Asymmetric Refractive Low Addition Multifocal IOL Implantation in Patients With Previous Hyperopic Corneal Laser Refractive Surgery.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2025. DOI: 10.3928/1081597x-20251024-02.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.