DOI 10.2500/aap.2022.43.210096
Evaluation of the ocular safety associated with the exhalation delivery system with fluticasone.
Аннотация
Background
Intranasal corticosteroids (INCS) are the cornerstone of treatment for chronic rhinosinusitis. Although INCS are generally considered safe and effective, there is a concern that chronic use may lead to ocular adverse effects.
Objective
To assess ocular safety of the exhalation delivery system with fluticasone propionate (EDS-FLU) in patients with chronic rhinosinusitis with nasal polyps.
Methods
Ocular safety data were collected during two randomized, double-blind, placebo controlled studies with open-label extensions. Ophthalmologists performed tonometry, slit-lamp, and visual acuity examinations to assess intraocular pressure (IOP) and the presence of cataracts. Ocular examinations were conducted before double-blind treatment, at the end of the 16-week double-blind phase, and at the end of the 8-week open-label phase. The results of pooled data from patients who received EDS-FLU 186 µg (n = 160), EDS-FLU 372 µg (n = 161), and EDS-placebo (n = 161) twice daily are reported here.
Results
At the end of the double-blind phase, six patients developed elevated average IOP > 21 mm Hg: two patients (1.2%) in the EDS-placebo group, three patients (1.9%) in the EDS-FLU 186 µg group, and one patient (0.6%) in the EDS-FLU 372 µg group. In addition, 6 of 482 patients developed cataracts: 3 patients in the EDS-placebo group, 2 patients in the EDS-FLU 186 µg group, and 1 patient in the EDS-FLU 372 µg group. At the end of the open-label phase, two additional patients showed IOP > 21 mm Hg and two additional patients developed cataracts.
Conclusion
No increased risk of elevated IOP was detected with EDS-FLU; the rate of cataract development was similar to EDS-placebo and to that reported with other INCS.Clinical trials NCT01622569 and NCT01624662, <ext-link xmlns:xlink="http://www.w3.org/1999/xlink" ext-link-type="uri" xlink:href="http://www.clinicaltrials.gov">www.clinicaltrials.gov</ext-link>.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.