Prospective pre-operative 3-T MR neurography peripheral nerve mapping of upper extremity amputations implanted with FAST-LIFE electrode interfaces of robotic hands: technical report.

Mogharrabi Bayan, Cheng Jonathan, Ratakonda Raghu, Keefer Edward, Chhabra Avneesh

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: Fascicular targeting of longitudinal intrafascicular electrode (FAST-LIFE) interface enables hand dexterity with exogenous electrical microstimulation for sensory restoration, custom neural recording hardware, and deep learning-based artificial intelligence for motor intent decoding. The purpose of this technical report from a prospective pilot study was to illustrate magnetic resonance neurography (MRN) mapping of hand and nerve anatomy in amputees and incremental value of MRN over electrophysiology findings in pre-surgical planning of FAST-LIFE interface (robotic hand) patients.

MATERIALS AND

METHODS

After obtaining informed consent, patients with upper extremity amputations underwent pre-operative 3-T MRN, X-rays, and electrophysiology. MRN findings were correlated with electrophysiology reports. Descriptive statistics were performed.

RESULTS

Five patients of ages 21-59 years exhibited 3/5 partial hand amputations, and 2/5 transradial amputations on X-rays. The median and ulnar nerve end bulb neuromas measured 10.1 ± 3.04 mm (range: 5.5-14 mm, median: 10.5 mm) and 10.9 ± 7.64 mm (2-22 mm, 9.75 mm), respectively. The ADC of median and ulnar nerves were increased at 1.64 ± 0.1 × 10-3 mm2/s (range: 1.5-1.8, median: 1.64 × 10-3 mm2/s) and 1.70 ± 0.17 × 10-3 mm2/s (1.49-1.98 × 10-3 mm2/s, 1.65 × 10-3 mm2/s), respectively. Other identified lesions were neuromas of superficial branch of the radial nerve and anterior interosseous nerve. On electrophysiology, 2/5 reports were unremarkable, 2/5 showed mixed motor-sensory neuropathies of median and ulnar nerves along with radial sensory neuropathy, and 1/5 showed sensory neuropathy of lateral cutaneous nerve of the forearm. All patients regained naturalistic sensations and motor control of digits.

CONCLUSION

3-T MRN allows excellent demonstration of forearm and hand nerve anatomy, altered diffusion characteristics, and their neuromas despite unremarkable electrophysiology for pre-surgical planning of the FAST-LIFE (robotic hand) interfaces.

Для цитирования: Mogharrabi Bayan, Cheng Jonathan, Ratakonda Raghu, Keefer Edward, Chhabra Avneesh. Prospective pre-operative 3-T MR neurography peripheral nerve mapping of upper extremity amputations implanted with FAST-LIFE electrode interfaces of robotic hands: technical report.. Skeletal radiology. 2022. DOI: 10.1007/s00256-022-04079-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.