DOI 10.1097/j.jcrs.0000000000001836

Медицинская библиотека · Journal of cataract and refractive surgery · 2026

Clinical outcomes of repositioning subluxated in-the-bag intraocular lenses using the flanged belt-loop technique with 6-0 polypropylene.

Yalçınkaya Çakır Gülay, Kırgız Ahmet, Liman Uzun Seda, Kandemir Beşek Nilay, Ahmet Sibel

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate the clinical outcomes of scleral fixation using the flanged belt-loop technique in patients with in-the-bag intraocular lens (IOL) subluxation after cataract surgery.

SETTING

Beyoglu Eye Training and Research Hospital, Turkey.

DESIGN

Retrospective.

METHODS

23 eyes of 23 patients who underwent scleral fixation of subluxated in-the-bag IOLs using the flanged belt-loop technique, with a minimum follow-up of 6 months, were included. All surgeries were performed by a single experienced surgeon. The procedure involved transscleral fixation of the existing IOL using 6-0 polypropylene sutures with flanged ends, without conjunctival dissection or use of scleral flaps. Preoperative and postoperative data were collected, including corrected distance visual acuity (CDVA), intraocular pressure (IOP), corneal endothelial cell density (ECD), and central corneal thickness (CCT).

RESULTS

The mean postoperative CDVA improved significantly ( P = .001). IOLs remained well-centered in 91.3% of eyes. Mild, asymptomatic decentration occurred in 2 eyes. There were no significant changes in IOP, ECD, or CCT ( P > .05). No major intraoperative or postoperative complications were reported. The surgical time was relatively short, and the technique caused minimal trauma to anterior segment structures. Bilateral haptic fixation was associated with better centration, especially after the initial learning curve.

CONCLUSIONS

The flanged belt-loop technique is a safe and effective option for repositioning subluxated in-the-bag IOLs, avoiding the need for IOL explantation. Its minimally invasive nature, short operative time, and stable outcomes make it a favorable alternative. Larger studies with longer follow-up are necessary to validate these findings and compare efficacy with other fixation methods.

Для цитирования: Yalçınkaya Çakır Gülay, Kırgız Ahmet, Liman Uzun Seda, Kandemir Beşek Nilay, Ahmet Sibel. Clinical outcomes of repositioning subluxated in-the-bag intraocular lenses using the flanged belt-loop technique with 6-0 polypropylene.. Journal of cataract and refractive surgery. 2026. DOI: 10.1097/j.jcrs.0000000000001836.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.