STUDY

OBJECTIVE

Currently the videographic review of emergency intubations is an unstructured, qualitative process. We created a taxonomy of errors that impede the optimal procedural performance of emergency intubation.

METHODS

This was a prospective, observational, study reviewing a convenience sample of deidentified laryngoscopy recordings of emergency department intubations that were qualitatively flagged before the study as demonstrating suboptimal technique. These videos were coded for the presence of 13 predetermined performance errors. Our primary outcome was the incidence of each of these specified errors during emergency intubation. Errors fell into 3 categories: errors of structure recognition during laryngoscope insertion, errors of vallecula manipulation, and errors of device delivery.

RESULTS

A total of 100 intubation attempts were reviewed. The most common error was inadequate lifting force with the blade tip in the vallecula which lowered the percent of glottic opening, occurring in 45% of the attempts. The least common performance error was the premature removal of the laryngoscope during bougie placement, occurring in only 9% of the videos.

CONCLUSION

We developed a taxonomy of 13 performance errors of laryngoscopy. Further study is warranted to determine how to best incorporate these into emergency airway training and the airway review process.

Для цитирования: Weingart Scott D, Barnicle Ryan N, Janke Alexander, Bhagwan Sabrina D, Tanzi Matthew, McKenna Peter J, Bracey Alexander, Resuscitationists Research Group. A taxonomy of key performance errors for emergency intubation.. The American journal of emergency medicine. 2023. DOI: 10.1016/j.ajem.2023.08.035.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.