MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/embc.2019.8857067

Медицинская библиотека · Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2019

Assessment of Lumbar Muscles Coordinated Activity Based on High-Density Surface Electromyography: A Pilot Study.

Jiang Naifu, Xue Jinwei, Li Guanglin

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Trunk-movement involves coordinated activity of different lumbar muscles. By assessing the lumbar muscles activity, the pathogeny of some neuromuscular disease might be revealed. Surface electromyography (sEMG) could be used to measure the muscle activity, but for assessing lumbar muscles coordinated activity, there lacks of an accurate and comprehensive application of sEMG. High-density (HD) sEMG provides a potential to assess lumbar muscles coordinated activity more accurately. Thus, in this pilot study, the objective was to assess the lumbar muscles coordinated activity based on HD sEMG. By placing a 5×15 array (75 channels) of HD sEMG electrodes to the surface of the low back area, the sEMG signal from four healthy subjects could be collected. In order to analyze the lumbar muscles coordinated activity, the sEMG signal during different trunk-movements was recorded. Through calculating the root-mean-square (RMS) of each channel and interpolating the RMS value between channels, the sEMG topography could be obtained. The high activity area in the topography showed a regular distribution during different trunk-movements. It might be useful for further assessment of lumbar disease such as low back pain.

Для цитирования: Jiang Naifu, Xue Jinwei, Li Guanglin. Assessment of Lumbar Muscles Coordinated Activity Based on High-Density Surface Electromyography: A Pilot Study.. Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference. 2019. DOI: 10.1109/embc.2019.8857067.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.