Scaffold Versus Repeat Drug-Coated Balloon Therapy for Early and Late Drug-Coated Balloon Restenosis in Femoropopliteal Arteries: Results of the RECURRENCE-2 Study.

Yanagiuchi Takashi, Tokuda Takahiro, Tanaka Akiko, Kojima Shunsuke, Yamaguchi Kohei, Takei Tatsuro, Yoshioka Naoki, Ogata Kenji, Nakama Tatsuya, Yokoi Hirokazu, LEADers PAD investigators

СтатьяМногоцентровое исследованиеСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

The current study aimed to investigate whether scaffolds or repeat drug-coated balloons (DCBs) were more effective in preventing recurrent restenosis after repeat endovascular therapy (EVT) for early (within 12 months) and late (after 12 months) DCB restenosis.

METHODS

This study retrospectively analyzed 234 limbs from 213 consecutive patients who underwent repeat EVT using scaffold (n = 52) or DCB only (n = 182) for primary DCB restenosis in femoropopliteal lesions at eight cardiovascular centers across Japan. Repeat EVT for early and late DCB restenosis was performed in 123 and 111 limbs, respectively.

RESULTS

Following repeat EVT, the freedom from recurrent restenosis rate was significantly higher with scaffolds than with DCBs for early DCB restenosis (81.6% vs. 62.3% at 12 months; p = 0.038), whereas no difference between treatment strategies was observed for late restenosis (80.0% vs. 85.9% at 12 months; p = 0.629). Among those who underwent repeat EVT for early restenosis, age ≤ 75 years (hazard ratio [HR], 2.05; 95% confidence interval [CI], 1.06-3.96; p = 0.031), male sex (HR, 2.12; 95% CI, 1.08-4.20; p = 0.029), and lesion length ≥ 150 mm (HR, 2.43; 95% CI, 1.31-4.52; p = 0.005) were significantly associated with recurrent restenosis, while scaffold use during repeat EVT was significantly associated with decreased recurrent restenosis (HR, 0.38; 95% CI, 0.17-0.81; p = 0.012).

CONCLUSION

Given the decreased rates of recurrent restenosis, scaffold implantation for DCB restenosis might be an acceptable strategy, particularly for early DCB restenosis after initial DCB.

Для цитирования: Yanagiuchi Takashi, Tokuda Takahiro, Tanaka Akiko, Kojima Shunsuke, Yamaguchi Kohei, Takei Tatsuro, Yoshioka Naoki, Ogata Kenji, Nakama Tatsuya, Yokoi Hirokazu, LEADers PAD investigators. Scaffold Versus Repeat Drug-Coated Balloon Therapy for Early and Late Drug-Coated Balloon Restenosis in Femoropopliteal Arteries: Results of the RECURRENCE-2 Study.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2025. DOI: 10.1002/ccd.31703.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.