DOI 10.1111/pace.13695

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2019

Cardiac conduction abnormalities associated with pacemaker implantation after transcatheter aortic valve replacement.

Cresse Stephen, Eisenberg Trevor, Alfonso Carlos, Cohen Mauricio G, DeMarchena Eduardo, Williams Donald, Carrillo Roger

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Complete heart block is a known complication after transcatheter aortic valve replacement (TAVR), often requiring pacemaker implantation within 24 hours of the procedure. However, clinical markers for delayed progression to complete heart block after TAVR remain unclear.

OBJECTIVES

We examined electrocardiographic data that may correlate with delayed progression to complete heart block and need for pacemaker.

METHODS

This is a single-center retrospective study of 608 patients who underwent TAVR between April 2008 and June 2017. We excluded 164 (27.0%) patients due to having a pacemaker before the procedure or expiring within 24 hours of the procedure (8, 1.3%). We excluded an additional 50 (8.2%) patients who received a pacemaker within 24 hours of the procedure. Electrocardiograms (EKGs) obtained after the procedure were compared to the preprocedural EKG to detect new changes.

RESULTS

Left bundle branch block, intraventricular conduction delay, left anterior fascicular block, and right bundle branch block were the most commonly seen conduction abnormalities after TAVR (25.1%, 10.9%, 7.5%, and 3.6%, respectively). Both left bundle branch block (odds ratio [OR] = 2.77 [95% confidence interval (CI): 1.24-6.22]) and right bundle branch block (OR = 13.2 [95% CI: 4.18-41.70]) carried an increased risk of pacemaker implantation after TAVR. Additionally, ΔPR greater than 40 ms from baseline also carried an increased risk of pacemaker implantation (OR = 3.53 [95% CI: 1.49-8.37]).

CONCLUSION

Left bundle branch block, right bundle branch block, and ΔPR greater than 40 ms were all associated with delayed progression to complete heart block and need for pacemaker implantation after TAVR.

Для цитирования: Cresse Stephen, Eisenberg Trevor, Alfonso Carlos, Cohen Mauricio G, DeMarchena Eduardo, Williams Donald, Carrillo Roger. Cardiac conduction abnormalities associated with pacemaker implantation after transcatheter aortic valve replacement.. Pacing and clinical electrophysiology : PACE. 2019. DOI: 10.1111/pace.13695.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.