MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/17434440.2023.2174850

Медицинская библиотека · Expert review of medical devices · 2023

Partial vs full glottic view with CMACTM D blade intubation of airway with simulated cervical spine injury: a randomized controlled trial.

Cheong Chao Chia, Ong Soon Yiu, Lim Siu Min, Wan A Wan Zakaria, Mansor Marzida, Chaw Sook Hui

Рандомизированное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: A previous study reported a shorter time to tracheal intubation by reducing percentage of glottic opening (POGO) view to <50% when intubating a normal adult airway using the GlidescopeTM blade. We evaluate the efficacy of reducing POGO to <50% when intubating patients with rigid cervical immobilization using CMACTM D blade.

METHODS

One hundred and four adult patients were randomized to group POGO 100% or POGO <50% . Laryngoscopy was performed by advancing tip of the D blade at vallecula. POGO 100% was achieved by exerting upward force to displace epiglottis until glottic opening from the anterior commissure to inter arytenoid notch. POGO < 50% was acquired by withdrawing the D blade tip dorsally from vallecula. The primary outcome was time to intubation.

RESULTS

The median time (IQR) to successful intubation was 29 (25-35) seconds for group POGO < 50% and 34 (28-40) seconds for group with POGO 100% (difference in medians, 5 seconds; 95% confidence interval, 2 to 8, p = 0.003). Complications were minor.

CONCLUSION

Using the CMACTM D blade with a reduced POGO in patients with cervical spine immobilization resulted in faster tracheal intubation.

TRIAL REGISTRATION: The trial is registered at ClinicalTrial.gov (CT.gov identifier: NCT04833166).

Для цитирования: Cheong Chao Chia, Ong Soon Yiu, Lim Siu Min, Wan A Wan Zakaria, Mansor Marzida, Chaw Sook Hui. Partial vs full glottic view with CMACTM D blade intubation of airway with simulated cervical spine injury: a randomized controlled trial.. Expert review of medical devices. 2023. DOI: 10.1080/17434440.2023.2174850.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.