MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.gie.2025.10.004

Медицинская библиотека · Gastrointestinal endoscopy · 2025

Lumen-apposing metal stents for partial reversal of Roux-en-Y gastric bypass: a multicenter study.

Kadkhodayan Kambiz, Hussain Azhar, Chandan Saurabh, Pathak Sagar J, Almujarkesh Mohamad Khaled, Abassi Abdullah, Viana Artur, Bellovincentelli Gustavo, Arain Mustafa, Cosgrove Natalie, Hayat Maham, Jain Deepanshu, Baig Muhammad Usman, Dahiya Dushyant Singh, Yang Dennis, Sampath Kartik, Bilal Mohammad, Sharaiha Reem Z, Hasan Muhammad, Irani Shayan S

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND AND AIMS: Roux-en-Y gastric bypass (RYGB) is an effective treatment of obesity; however, some patients may develop debilitating postoperative adverse events requiring surgical reversal, which can be technically challenging and highly morbid. Endoscopic ultrasound (EUS)-guided placement of a lumen-apposing metal stent (LAMS) offers a minimally invasive option that creates a gastrogastric fistula. Partial redirection of food into the native stomach results in improvement of nutritional status and may serve either as a bridge to surgery or as definitive therapy.

METHODS

We report a prospective series of 16 patients with adverse events related to RYGB, from 4 tertiary care centers, who underwent EUS-guided LAMS placement and creation of a gastrogastric fistula due to either severe protein-calorie malnutrition, dumping syndrome, or postprandial hyperinsulinemic hypoglycemia.

RESULTS

Technical and clinical success was achieved in 16 patients (100%) and 15 patients (93.75%), respectively. The median procedure duration was 30 minutes (range, 18-76 minutes). The mean body mass index increased significantly from the time of placement of a LAMS to a mean follow-up of 15.8 months (range, 3-62 months), 21.2 kg/m2 (range, 12.5-33.4 kg/m2) to 24.4 kg/m2 (range, 19.9-32.3 kg/m2) (mean difference: 3.19, P = .002). In addition, there was a statistically significant increase in mean hemoglobin and serum albumin at follow-up. Although there were no procedure-related adverse events, LAMS-related adverse events occurred in 4 patients and included pain, tissue ingrowth, and stent migration.

CONCLUSIONS

EUS-guided LAMS placement is a safe, efficacious, and minimally invasive strategy for partial reversal of RYGB either as a bridge to definitive surgical reversal or as destination therapy.

Для цитирования: Kadkhodayan Kambiz, Hussain Azhar, Chandan Saurabh, Pathak Sagar J, Almujarkesh Mohamad Khaled, Abassi Abdullah, Viana Artur, Bellovincentelli Gustavo, Arain Mustafa, Cosgrove Natalie, Hayat Maham, Jain Deepanshu, Baig Muhammad Usman, Dahiya Dushyant Singh, Yang Dennis, Sampath Kartik, Bilal Mohammad, Sharaiha Reem Z, Hasan Muhammad, Irani Shayan S. Lumen-apposing metal stents for partial reversal of Roux-en-Y gastric bypass: a multicenter study.. Gastrointestinal endoscopy. 2025. DOI: 10.1016/j.gie.2025.10.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.