Electrocardiogram (ECG) patterns of left anterior fascicular block and conduction impairment in ventricular myocardium: a whole-heart model-based simulation study.

Gao Yuan, Xia Ling, Gong Ying-Lan, Zheng Ding-Chang

СтатьяПеревод в очереди

Аннотация

Left anterior fascicular block (LAFB) is a heart disease identifiable from an abnormal electrocardiogram (ECG). It has been reported that LAFB is associated with an increased risk of heart failure. Non-specific intraventricular conduction delay due to the lesions of the conduction bundles and slow cell to cell conduction has also been considered as another cause of heart failure. Since the location and mechanism of conduction delay have notable variability between individual patients, we hypothesized that the impaired conduction in the ventricular myocardium may lead to abnormal ECGs similar to LAFB ECG patterns. To test this hypothesis, based on a computer model with a three dimensional whole-heart anatomical structure, we simulated the cardiac exciting sequence map and 12-lead ECG caused by the block in the left anterior fascicle and by the slowed conduction velocity in the ventricular myocardium. The simulation results showed that the typical LAFB ECG patterns can also be observed from cases with slowed conduction velocity in the ventricular myocardium. The main differences were the duration of QRS and wave amplitude. In conclusion, our simulations provide a promising starting point to further investigate the underlying mechanism of heart failure with LAFB, which would provide a potential reference for LAFB diagnosis.

Для цитирования: Gao Yuan, Xia Ling, Gong Ying-Lan, Zheng Ding-Chang. Electrocardiogram (ECG) patterns of left anterior fascicular block and conduction impairment in ventricular myocardium: a whole-heart model-based simulation study.. Journal of Zhejiang University. Science. B. 2018. DOI: 10.1631/jzus.b1700029.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.