Evaluation of acoustic shock induced early hearing loss with audiometer and distortion product otoacoustic emissions.
Аннотация
BACKGROUND
Acoustic shock injury has been described as a permanent injury to the auditory system either due to daily noise dose of in excess of 85 decibels or very loud impulse sound reputed to be in excess of 120 decibels and acoustic incidents. This study was performed to compare the results of audiogram and the newer diagnostic method distortion product otoacoustic emissions (DPOAEs) parameters due to acoustic shock injury in call center professionals working in a noisy environment and prone to acoustic injury.
MATERIALS AND
METHODS
Hearing functions of 340 subjects were first assessed with pure tone audiometry and then DPOAEs results were compared among acoustic shock exposed subjects with normal audiogram and those with abnormal audiogram.
RESULTS
Out of 340 acoustic shock exposed subjects 304 were normal on audiometric testing and 34 had abnormal audiograms. Subsequently on DPOAE testing out of 304 acoustic shock exposed subjects with normal audiogram 125 failed and 181 passed.
CONCLUSIONS
This study showed that DPOAEs are more sensitive than audiometry to detect pre-symptomatic inner ear damage. It may play a role as screening and monitoring test for acoustic shock-exposed workers.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.